background image

If fuel level is low, refill with
mixed fuel.
Be sure to use the fuel filter screen
on the fuel filter neck.

LEVEL

Fuel filter screen

Fuel tank cap

Do not refuel while smoking or near open flame or other such
potential fire hazards. Otherwise fire accident may occur.

CHECK MIXED FUEL

Make sure you review each warning in order to prevent fire hazard.

Do not refill tank while engine is running or hot.
Close fuel valve before refueling with fuel.
Be careful not to admit dust, dirt, water or other foreign objects Into

fuel.
Wipe off spilt fuel thoroughly before starting engine.
Keep open flames away.

WARNING

WARNING

TP18001

 . . . . . . . . . . . . . . . . . 4 /1.06

TP18001

-5. . . . . . . . . . . . . . . .  4 /1.06

U

TP18001

 . . . . . . . . . . . . . . . .

 

4 /1.06

Fuel Amount

up to "LEVEL" position :

(L/Gal)

  

8

Содержание TP18001

Страница 1: ...800W TP18001 TP18001 5 UTP18001 GASOLINE GENERATOR One Stop Tools Station...

Страница 2: ...al injury or equipment damage if instructions are not followed NOTE Gives helpful information If a problem should arise or if you have any questions about the generator consult an authorized dealer or...

Страница 3: ...wever the generator will vibrate on an irregular surface so choose a level place without surface irregularities If the generator is tilted or moved during operation fuel may spill and or the generator...

Страница 4: ...t pour water directly over the generator nor wash it with water WARNING Be extremely careful that all necessary electrical grounding procedures are followed during each and every use Failure to do so...

Страница 5: ...ns are subject to change without notice Displacement Air cooled 2 stroke Gasoline Engine Length Width Height 13 Fuel type Mixed fuel Fuse less circuit breaker V Rated current 12 A HP min 1 Safety devi...

Страница 6: ...uel cap 3 Fuel tank 4 Recoil starter handle 5 Engine on off switch 6 Choke lever 7 Air filter housing 8 AC socket 9 Reset button 10 Exhaust 11 Motor cover 12 DC socket 13 DC charging leads 14 Spark pl...

Страница 7: ...l into the container then add the correct proportion of two stroke oil according to the chart shown below When the correct ratio has been mixed tighten the container cap and agitate the container to e...

Страница 8: ...dent may occur CHECK MIXED FUEL Make sure you review each warning in order to prevent fire hazard Do not refill tank while engine is running or hot Close fuel valve before refueling with fuel Be caref...

Страница 9: ...operate generator in a dry well ventilated area Keep exhaust pipe clear of foreign objects Keep generator away from open flame No smoking Keep generator on a stable and level surface Do not block gen...

Страница 10: ...he starter handle slowly until passing the compression point resistance will be felt then return the handle to its original position and pull briskly If the engine fails to start after several attempt...

Страница 11: ...fore connecting it to the generator Do not move the generator while it is running Be sure to ground the generator if the connected appliance is grounded Failure to ground unit may lead to electrical s...

Страница 12: ...the generator if the connected electrical device Is grounded WARNING TWIST up to 30A up to 20A 110 120V 110 120V 220 240V GFCI Ground Fault Circuit Interrupter Receptacle duplex REC1 Locking Receptac...

Страница 13: ...witch of the electric equipment and unplug the cord from receptacle of the generator b Allow the engine about 3 minutes to cool down at no load before stopping c Turn the engine switch to the position...

Страница 14: ...fluorescent lamps require 1 2 to 2 times the indicated wattage during start up Loads for mercury lamps require 2 to 3 times the indicated wattage during start up Electrical motors require a large sta...

Страница 15: ...rsepower 500 300 1 6 Horsepower 750 500 1 4 Horsepower 1000 600 1 3 Horsepower 1400 700 1 2 Horsepower 2350 875 Television Tube type 300 300 Flat Screen 20 120 120 Flat Screen 46 190 190 Coffee Maker...

Страница 16: ...0 Monitor LCD style 30 30 Printer 400 600 400 600 Hot Water Heater 4500 4500 Garage Door Opener 1420 720 Recreational Applications Approximate Starting Wattage Approximate Running Wattage Television T...

Страница 17: ...proximate Running Wattage Air Compressor 1 2 hp 1600 975 1 hp 4500 1600 Bench Grinder 8 in 2500 1400 Circular Saw Heavy Duty 7 1 4 in 2300 1400 Concrete Vibrator 1 2 hp 840 avg 840 avg 1 hp 1080 avg 1...

Страница 18: ...1050 400 1 3 Horsepower 1350 450 Horsepower 1800 600 Horsepower 2600 850 1 Horsepower 3000 1000 1 Horsepower 4200 1600 2 Horsepower 5100 2000 3 Horsepower 6800 3000 4 Horsepower 9800 4800 Capacitor St...

Страница 19: ...op or loss occurs in the extension cord which reduces the effective voltage available for the appliance or tool The chart below has been prepared to illustrate the approximate voltage loss when an ext...

Страница 20: ...n control system consists of the following parts The maintenance schedule indicated in the table is based on the normal generator operation Should the generator be operated in extremely dusty conditio...

Страница 21: ...and nuts Daily Daily Yearly Daily Daily Check and refill engine oil Change engine oil Note1 Clean spark plug Clean air cleaner Replace air cleaner element Clean fuel filter Check and replace carbon b...

Страница 22: ...the electrode gap to 0 6 to 0 7 mm 0 024 to 0 028 in Gap 0 6 to 0 7 mm 0 024 to 0 028 in CLEANING FUEL STRAINER Dirt and water in the fuel are removed by the fuel strainer a Remove the strainer cup a...

Страница 23: ...ition If closed open fuel valve Check to make sure generator is not connected to an appliance Check spark plug for loose spark plug cap Check spark plug for contamination Check if engine switch is in...

Страница 24: ...1 1 54 Screw M3 8 Ratchet 1 1 19 1 1 55 Collar Reel 1 1 20 1 1 56 Spiral spring 1 1 21 1 1 57 Screw M6 12 Starter handle 1 1 22 1 1 58 Spring Washer 6 Rope 1 1 23 1 1 59 Washer 6 Fan case 1 1 24 1 1 6...

Страница 25: ...TP18001 TP18001 5 UTP18001 Exploding view Engine 25...

Страница 26: ...ilter element Fuel tank cap Screw M6 18 1 48 Oil cap Screw M4 16 1 49 Fuel filter AC receptacele 1 50 1 18 Earth lead DC protector 1 51 DC protector 1 52 Circult connector Screw M3 8 1 53 Control box...

Страница 27: ...TP18001 TP18001 5 UTP18001 Exploding view Generating Setassembly 27...

Страница 28: ...800W GASOLINE GENERATOR T0816 V11 MADE IN CHINA www totaltools cn TOTAL TOOLS CO LIMITED One Stop Tools Station...

Отзывы: