4
Additional safety warnings
•
Wait for the cutter to stop before leaving the tool.
An exposed rotary cutter can catch on the surface and cause possible loss of
control and serious injury.
•
Hold the power tool only by the insulated gripping surfaces, as the cutter may
come into contact with its own cord.
Cutting a "live" wire can cause the exposed metal parts of the power tool to be
"live" and could cause an electric shock to the operator.
•
Use clamps or other practical way to secure and support the workpiece on a
stable platform.
Holding the work by hand or against the body leaves it unstable and can lead to
loss of control.
Other risks
Even when the power tool is used as prescribed, it is not possible to eliminate all residual
risk factors:
a. Health defects resulting from the emission of vibrations if the power tool is used
for a longer period of time or if it is not properly managed and maintained.
b. Injury and property damage from broken accessories suddenly breaking.
Caution
This power tool produces an electromagnetic field during operation. This
field can, in some circumstances, interfere with active or passive medical
implants.
To reduce the risk of serious injury, we recommend that individuals with
medical implants consult their physician before using this power tool.
If the cord is damaged or cut during work, do not touch the cord, immediately unplug the
tool. Never use the machine with a damaged cord.
The machine must not be damp and must not be used in a humid environment.
Attention
Safe working with this machine is only possible when the operating or safety
information is fully read and the instructions contained therein are strictly
followed.
Technical data
Data sheet
Voltage
220-240V ~ 50 / 60Hz
Power
1050W
No-load speed
16000 / min
Planning depth
0-3mm
Planning width
82mm