3.
I
n the event of a burnback, where the flame burns back to the jet, immediately turn off the gas supply at the control valve on the front panel. After
ensuring the flame is extinguished, re-light the appliance in the normal manner. Should the appliance again burn back, close the control valve and
call a service technician to examine the appliance. Do not use the appliance again until the service technician has declared that it is safe to do so.
4.
If there is an apparent gas leak, (smell of gas) close the control valve on the appliance . Make sure that there are no naked flames within 5 metres
of the appliance and check for leaks as described below.
Additional information sheet to be read in conjunction with the manufacturer’s
instruction booklet. The information below is only applicable to the following Totai
LPG gas stoves with gas cooker burners and a gas oven supplied for use in South
Africa.
Model numbers : F6T40G2(03/T700) & F9H50G2(03/T800)
1.
This appliance may only be installed by a registered LP Gas installer
. All registered installers are issued with a card carrying their
registration number. Ask to be shown the card before allowing the installation work to commence and make a note of the Installer registration
number as well as the installer scope of work as indicated on the back of the card. Be aware that the registration card indicates on the back, the type
of gas that installer is registered to work with . An installer that is registered to work with LPG installations might not be registered to work on Natural
Gas installations. Similarly, an installer that is registered to work with Natural Gas installations might not be registered to work on LPG installations.
Upon completion of the installation, the installer is required to explain the operational details of the appliance together with the safety instructions.
You will be asked to sign acceptance of the installation and be provided with a completion certificate. You should only sign for acceptance of the
installation when the installation is completed to your satisfaction.
The appliances have been designed specifically for use only with LPG and may not be used with any other gas than that for which it has
been designed, The manufacturer’s international user instruction booklet refers to a Natural gas conversion option. The does not apply
to the South African models
The installation is required to comply with the requirements of SANS 10087-1.
It is important to note that if the appliance is not installed by the appropriate grade of registered installer, the installation will be illegal , your insurance
company may refuse to pay out any claims in the event of an incident, and the manufacturer’s warranty will be invalid.
Note that your invoice is required in the event that you wish make a guarantee claim. Read carefully the specific warranty conditions on the reverse.
2.
The stoves require an operating pressure of 2,8 kPa at the appliance. A suitable LPG regulator that complies with the requirements of SANS
1237 must be installed outside.
5. Should you suspect a leak at the cylinder connections (outside the house) then apply the soapy water solution to the visible joints such as where
the regulator fits into the cylinder or where the regulator fits into the flexible hose, or the joints on the manifold if fitted. If there is a
Ieak then a bubble
or bubbles will form. If you are unable to stop a leak at this point then turn off the cylinder valve or valves and call a service technician to correct the
fault. As with leaks inside the premises do not use the appliance until the service technician has declared that it is safe to do so.
Igniting and shutting down the burners
Avoid opening the oven door during cooking as this will affect the cooking time. Examine the food through the window in the oven door.
Never place any food or container on the oven floor.
Pre heat the oven for 10 minutes on a medium heat before placing any food in the oven.
Never check for gas leaks with a naked flame as this is extremely dangerous. To check for a gas leak, use a brush dipped in a soapy water solution
(e.g. water with dishwashing liquid added) and apply the solution to all the joints in the system. If there is a leak then turn off the gas supply at the
isolation valve which the installer will provide as a part of the installation. Call a service technician to examine the appliance and do not use the
appliance until the service technician has declared that it is safe to do so.
Each burner may be individually ignited by pushing in and then turning the relevant control knob (identified in Figs 1 and 2) in and anti clockwise
ditrectiom to the high flame position and then pushing in and holding in the right hand ignitor button for the cooker burners and the left hand ignitor
button for the grill and oven burners. Release the ignitor button once the required burner is lit.
Adjust the flame intensity of the burners by turning the relevant control knob to the off position (see Fig 1 and 2)
When cooking using the cooker burners always use the burner that suits the pot size. For pots smaller than 200 mm diameter use the medium
auxiliary burner. For larger pots use the large burners. This will ensure that you will achieve the best cooking efficiency. If the flame appears to
extend up the sides of the pot either place the pot on a smaller burner or reduce the flame height by adjusting the required burner control knob.
Using the stove
When placing food in the oven, always place the food on the wire grid supplied with the stove. Best results will be obtained with the grid in the middle
position.
When using the oven, always open or close the oven door slowly to avoid air movement which could affect the flame.
Issue 1-2020
These appliances comply with the requirements of SANS 1539.
Permit number :1051-XXX/l-17-A
Distributed by: D.K.Gas Appliances. PO Box 34191 Erasmia 0023
website:
email: [email protected]
www.totai.co.za