Controller functions

RES-403

Page 27

You should always wait for the heatsealing
band and the bar to cool down (to ambient

temperature) before activating the AUTOCAL
function.

Reasons for disabled AUTOCAL function:

1. The AUTOCAL function cannot be activated until

10 seconds after the controller is switched on. If you
attempt to activate it sooner, it will not function.

2. The AUTOCAL function is not activated if the heat-

sealing band is cooling down at a rate of more than
0.1K/sec. If the control signal is activated, the
function is activated automatically providing the
cooling rate has fallen below the above mentioned
value.

3. If the "START" signal (24VDC) is active, the

AUTOCAL function is not executed ("HEAT" LED
lit).

4. AUTOCAL cannot be activated if error codes

101…103, 201…203, 801 or 9xx (up to September
2005: error codes 1…3, 5…7) occur at start-up.
AUTOCAL cannot be activated with error codes
201…203, 801 or 9xx (up to September 2005: error
codes 5…7). If the controller has operated correctly,
at least one time, after start-up (

ª

section 9.12

"Error messages" on page 31).

If the AUTOCAL function is disabled and if
you attempt to activate it then the

"AUTOCAL" LED blinks.

9.5

"START" signal (HEAT)

When the "START" signal is activated, the controller-
internal set/actual comparison is enabled and the heat-
sealing band is heated up to the SET temperature. It
remains at this temperature until the signal is deacti-
vated.
The "HEAT" LED on the front panel of the RES-403 is
lit continuously for the duration of the heating phase.
The "START" signal can be activated in two ways:

• By means of a 24VDC signal at terminals 12+13

or

• By means of a control contact at terminals 15+18

The "START" signal is disabled as long as the
AUTOCAL function is executing

("AUTOCAL" LED lit, "HEAT" LED blinks).

The terminals 15+18 are not potenial-free and
might have the potential of the secondary

voltage of the impulse transformer. For the termi-
nals of the control contact touch voltage protection
must be installed. External grounding is not
allowed. If this warning is ignored, the controller
will be damaged by frame currents.

The set point that is selected for the heatsealing tempe-
rature must be greater than 40°C. If not, the heat-
sealing band will not be heated up ("HEAT" LED
blinks).

!

!

13

12

RES- 403

max. 6mA

START

(HEAT)

24VDC

LOW:     2VDC

START

(HEAT)

HIGH:    12VDC

GND

15

18

RES- 403

max.

5mA

0V

START

(HEAT)

with

contact

!

!

Содержание ROPEX RESISTRON RES-403

Страница 1: ...Automatic optimization AUTOTUNE Automatic configuration of the secondary voltage and current ranges AUTORANGE as of October 2005 Automatic phase angle compensation AUTOCOMP as of October 2005 Automat...

Страница 2: ...signal MOD 40 or Temp OK signal MOD 46 17 8 9 Startup and operation 18 8 10 View of the controller 18 8 11 Controller configuration 18 8 12 Replacing and burning in the heat sealing band 20 8 13 Start...

Страница 3: ...fied as follows e g Alloy 20 TCR 1100 ppm K NOREX TCR 3500 ppm K The RESISTRON temperature controller must be set and coded according to the temperature coefficient of the heatsealing band The use of...

Страница 4: ...d on the user s own responsibility The CE marking on the controller confirms that the device itself complies with the above mentioned standards It does not imply however that the overall system also f...

Страница 5: ...rmal loads on the heat sealing band are detected and can be corrected quickly and precisely A highly high response thermo electric control loop is formed which is highly accurate because purely elec t...

Страница 6: ...ectrically isolated from the controller and the heating circuit Coding switches on the temperature controller itself can be used to adapt to different heatsealing band alloys Alloy 20 NOREX etc and se...

Страница 7: ...y currents continuous current 5A pulsed current 25A Line filter Essential in order to ensure CE conformity Optimized for the RESISTRON temperature controller Impulse transformer Designed according to...

Страница 8: ...oftware section 9 10 Diagnostic interface visualization software as of October 2005 on page 30 If the actual temperature is inside the specified tolerance band when the START signal is activated the o...

Страница 9: ...and temperature coefficient settings can also be specified by means of the ROPEX visualization software section 9 10 Diagnostic interface visualization software as of October 2005 on page 30 in addit...

Страница 10: ...be allowed between them The moving clip required for fastening must be facing down for mounting on a horizontal top hat rail End holders to mechanical fix the controller must be fitted at both ends f...

Страница 11: ...RON temperature controller in the range from 47Hz 63Hz 3 Install the RESISTRON temperature controller in the electrical cabinet on a standard top hat rail DIN TS35 rail according to DIN EN 50022 If se...

Страница 12: ...itable temperature coefficient 20mm clearance if several controllers installed on one top hat rail Note polarity No additional resistance in secondary circuit Dimension transformer correctly Secondary...

Страница 13: ...nging to the 4xx Series Relay Kb Load break all pole e g in combination with the alarm output of the temperature controller When using a series resistor RV 1 the relay Kb shall be installed Impulse Tr...

Страница 14: ...plication For more technical information Line filter docu mentation It is permissible to supply several RESIS TRON control loops with a single line filter providing the total current does not exceed t...

Страница 15: ...GND 13 12 5 6 8 Contact closed or opened by ALARM see configuration 11 9 10 7 START HEAT with contact 14 15 18 17 16 cw 2K SET POINT POTENTIOMETER PD 3 or PD 5 Cable shielded C ATR _ ANALOG OUTPUT 0 1...

Страница 16: ...8 Contact closed or opened by ALARM see configuration 0V Internnal ground No external grounding allowed R Current transformer PEX W2 W3 Impuls transformer 11 9 10 7 IR UR Heat sealing band START HEAT...

Страница 17: ...nnot be used in combination with MOD 26 booster connection manufactured prior to September 2005 MOD 46 cannot be used in combination with MOD 40 Additional terminals in housing cover for MOD 26 Booste...

Страница 18: ...igured in the range from 0 4VAC to 120VAC and the current in the range from 30A to 500A If the voltage and or the current is outside the permissible range a detailed error message appears on the contr...

Страница 19: ...ction 9 10 Diagnostic interface visualization soft ware as of October 2005 on page 30 3 2 1 4 5 ON OFF 1 10V 6 60V 20 120V ON OFF OFF OFF ON OFF OFF OFF ON 30 100A 60 200A 120 400A OFF ON ON OFF OFF O...

Страница 20: ...Too low a TCR leads to oscilla tion or uncontrolled heating When heatsealing bands with a higher TCR are used the controller must be calibrated for this The first time the heatsealing band is heated t...

Страница 21: ...voltage 6 When the voltage is switched on the yellow AUTOCAL LED lights up for approximately 0 3 seconds to indicate that the controller is being powered up correctly As of SW Revision 106 If the red...

Страница 22: ...e is displayed please proceed as des cribed in section 9 12 Error messages on page 31 9 Burn in the heatsealing band section 8 12 Replacing and burning in the heatsealing band on page 20 and repeat th...

Страница 23: ...on of AUTOCAL process Green LED indicates pulses in measure ment mode In control mode luminous intensity is proportional to heating current Yellow LED lit during heating phase Red LED lights up or bli...

Страница 24: ...nts If a ROPEX PD x precision potentiometer is used the SET temperature can be adjusted exactly with the help of the digital display in the window of the dial The number which appears on the display c...

Страница 25: ...OPEX ATR x temperature indicator size scaling dynamic response are ideally suited to this application and this instrument should the refore always be used section 5 Accessories and modifications on pa...

Страница 26: ...ion software section 9 10 Diagnostic interface visualization soft ware as of October 2005 on page 30 This setting is remembered if the controller is switched off and then on again As of SW Revision 10...

Страница 27: ...ction is disabled and if you attempt to activate it then the AUTOCAL LED blinks 9 5 START signal HEAT When the START signal is activated the controller internal set actual comparison is enabled and th...

Страница 28: ...gle displacement between the UR and IR measuring signals for special heatsealing applications ROPEX Application Report The AUTOCOMP function is provided for this purpose It is executed whenever the AU...

Страница 29: ...rror code 309 310 is indicated and the alarm relay is switched An additional delay time 0 9 9s can be set in the ROPEX visualization software The first time the lower tolerance band limit is exceeded...

Страница 30: ...es 10 12 3 Lit continuously This indicates that a fault is preventing the controller from being started error codes 101 103 107 108 201 203 307 308 801 9xx up to September 2005 error codes 1 7 As a ru...

Страница 31: ...ober 2005 The block diagram in section 9 13 Fault areas and causes on page 36 permits each fault to be cleared quickly and efficiently 13 voltage levels for fault diagnostics appear at the actual valu...

Страница 32: ...Replace controller Check plug in jumper Cause I R signal missing U R signal missing U R and I R signals missing Temperature step down Temperature step up Temperature too low high section 9 8 Frequenc...

Страница 33: ...or fault area fgh loose contact Run AUTOCAL Cause I R signals incorrect incorrect specification of impulse transformer U R signals incorrect incorrect specification of impulse transformer U R and or...

Страница 34: ...lerbereich i Konfiguration pr fen Fehlerbereich ij Konfiguration pr fen Cause I R signal incorrect calibration not possible U R signal incorrect calibration not possible U R and I R signals incorrect...

Страница 35: ...missing Temperature step Frequency fluctuation inadmissible line frequency Internal fault Internal fault controller defective U R and or I R signal incorrect Data error I R signal incorrect calibrati...

Страница 36: ...pulse transformer interrupted Secondary circuit interrupted before UR pickoff point Wire break Secondary winding of impulse transformer interrupted e UR signal missing Measuring wires interrupted f Pa...

Страница 37: ...or incorrectly connected Fault area Explanation Possible causes DIP switches for secondary voltage U2 and current I2 up to September 2005 U2 6 60VAC I2 30 100A DIP switches 2 ON 1 3 4 5 OFF These swi...

Страница 38: ...rminals including the terminals for the winding connections on the impulse transformer is recommended Dust depo sits on the controller can be removed with dry com pressed air Measuring impuse duration...

Страница 39: ...s of the controller and the required modifications optional in all orders e g RES 403 400VAC MOD 26 controller for 400VAC power supply with booster connection Art No 740303 800026 must be ordered Curr...

Страница 40: ...How to order Page 40 RES 403 For more accessories Accessories leaflet Booster B 400 075 Max pulse load 75A 400VAC Art No 885301 100 Max pulse load 100A 400VAC Art No 885304...

Страница 41: ...g band type 9 Heatup timeout 29 How to order 39 I Impulse heatsealing method 4 Impulse transformer 7 13 39 Installation 10 11 Installation procedure 11 Installation regulations 11 L Line filter 7 13 1...

Страница 42: ...403 Temperature range 9 19 Temperature reached signal 8 17 Temperature setting 24 Transformer 3 7 13 39 Type of construction 9 V View of the controller 18 Visualization software 30 W Wiring 11 13 Wir...

Отзывы: