WX9 ASD Installation and Operation Manual
141
Synchronized Torque Bias Input Selection
Program
Torque
Torque Control
This parameter Enables/Disables the
Synchronized Torque Bias
input
function. When enabled, this parameter identifies the source of the
Synchronized Torque Bias
input signal.
Settings:
0 — Disabled
1 — VI/II
2 — RR
3 — RX
4 — RX2
5 — CN8 Option
6 — Binary/BCD Input
7 — Common Serial (TTL)
8 — RS232/RS485
9 — Communication Card
Direct Access Number — F422
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Tension Torque Bias Input Selection (Torque Control)
Program
Torque
Torque Control
This parameter Enables/Disables the
Tension Torque Bias
input function.
When enabled, this parameter identifies the source of the
Tension Torque Bias
input signal.
Settings:
0 — Disabled
1 — VI/II
2 — RR
3 — RX
4 — RX2
5 — CN8 Option
6 — Binary/BCD Input
7 — Common Serial (TTL)
8 — RS232/RS485
9 — Communication Card
Direct Access Number — F423
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Load Sharing Gain Input Selection
Program
Torque
Torque Control
This parameter Enables/Disables the
Load Sharing Gain
input function and is
enabled by selecting a
Load Sharing Gain
input signal source.
Settings:
0 — Disabled
1 — VI/II
2 — RR
3 — RX
4 — RX2
5 — CN8 Option
6 — Binary/BCD Input
7 — Common Serial (TTL)
8 — RS232/RS485
9 — Communication Card
Direct Access Number — F424
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Содержание WX9 ASD
Страница 1: ...WX9 ASD Install Op Manual TOSHIBA WX9 ASD INSTALLATION OPERATION MANUAL DN 68940 000 March 2014 ...
Страница 2: ......
Страница 3: ...DN 68940 000 March 2014 WX9 ASD Installation Operation Manual ...
Страница 4: ......
Страница 12: ...iv WX9 ASD Installation and Operation Manual ...
Страница 213: ...WX9 ASD Installation and Operation Manual 201 Figure 32 WX9 ASD Enclosure Dimensions Dimensions are in in mm ...
Страница 225: ......