116
WX9 ASD Installation and Operation Manual
Jog Frequency
Program
Frequency
Jog Settings
This parameter sets the output frequency of the drive during a
Jog
.
Jogging
is
the term used to describe turning the motor on for small increments of time and
is used when precise positioning of motor-driven equipment is required.
The
Jog
function may be initiated from the
EOI
, remotely via the
Terminal
Board
,
or
using
Communications
(for additional information on using
Communications
for
Jogging
, see the
Communications
manual).
To perform a
Jog
, set this parameter to the desired
Jog
frequency.
Select a
Jog Stop
method (
).
Jog Using the Terminal Board
To initiate a
Jog
from the
Control Terminal Strip
,
perform the following:
1.
Assign a discrete input terminal to the
Jog
function (see
2.
Assign a discrete input terminal to the
F
(
Forward
) function (and
Reverse
if required) (see
).
3.
Provide a
Forward
and/or
Reverse
command from the
Terminal
Board
.
4.
Place the system in the
Auto
mode (Hand/Auto LED is off).
5.
Connect the assigned
Jog
terminal (from step
CC
for the desired
Jog
duration.
The system will run at the
speed for the duration of the terminal activation
and will stop using the
Jog Stop Pattern
method upon terminal
deactivation.
Direct Access Number — F260
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 20.00
Units — Hz
Jog Stop Pattern
Program
Frequency
Jog Settings
This parameter sets the stopping method used while operating in the
Jog
mode.
Note:
This parameter setting is used for the
Jog
operation only. The
Emergency Off
stopping method setting of
has priority
over this setting and changes made here do not affect the
function or setting of
Settings:
0 — Deceleration
1 — Coast
2 — DC Injection
Direct Access Number — F261
Parameter Type —
Selection List
Factory Default —
Deceleration
Changeable During Run —
Yes
Содержание WX9 ASD
Страница 1: ...WX9 ASD Install Op Manual TOSHIBA WX9 ASD INSTALLATION OPERATION MANUAL DN 68940 000 March 2014 ...
Страница 2: ......
Страница 3: ...DN 68940 000 March 2014 WX9 ASD Installation Operation Manual ...
Страница 4: ......
Страница 12: ...iv WX9 ASD Installation and Operation Manual ...
Страница 213: ...WX9 ASD Installation and Operation Manual 201 Figure 32 WX9 ASD Enclosure Dimensions Dimensions are in in mm ...
Страница 225: ......