E6581187
-
5
-
2.2. In case of ATFIN7*6
Attachable inverter models
VFA7-2750P1, -4110KP1, -4132KP1
VFP7-2750P, -4110KP, -4132KP, -4160KP
Step 1: Remove the inverter fitting metal
①
(4 pcs),
hanging metal
②
(2 pcs) and screw
③
(4 pcs)
shown in Figure 3 from the inverter.
Step 2: First, fit the top and bottom attachments to the inverter, next fit the side attachments to the inverter with
the screws supplied with the attachment as shown in Figure 4.
(For fitting the bottom attachment, remove the front cover of the inverter beforehand.)
[2] Top attachment
①
①
①
①
②
②
③
③
[1] Bottom attachment
M4
×
10
M5
×
12
Figure 3
[3] Side attachments
Reuse the screws
②
and
③
removed in
the step 1.
M5
×
12
M4
×
10
Figure 4
Among the screws supplied with the attachment,
the following screws remain as unused.