background image

E6582140

Multi-layer shielded cable is recommended.
When wiring, follow the instructions bellow.
- Use twisted pair wire for A/NA, B/NB and PGVC/PGCC each
- For PGVC, select a pin according to the encoder supply specification.

Parameter configuration is also needed (See instruction manual)

- Do not connect any wire to unused pins
- Recommended wire size is 0.25 mm

2

 (AWG26) for signal line (A, NA, B and NB), 

0.5mm

2

 (AWG20) for power supply (PGVC and PGCC)

- The cable length is 100m at maximum. At that time, supply voltage drop by wire 

impedance should be taken into account.

Mounting

Removing

Outline drawing

Any part of the Digital Encoder option that is proved to be defective will be repaired 
and adjusted free of charge under the following conditions:
1. This warranty applies only to the option unit.
2. Any part of the option which fails or is damaged under normal use within twelve 

months from the date of delivery will be repaired free of charge.

3. For the following kinds of failure or damage, the repair cost shall be borne by the 

customer even within the warranty period.
i) Failure or damage caused by improper or incorrect use or handling, or 

unauthorized repair or modification of the option.

ii) Failure or damage caused by falling or an accident during transportation after 

the purchase.

iii) Failure or damage caused by fire, salty water or wind, corrosive gas, 

earthquake, storm or flood, lightning, abnormal voltage supply, or other natural 
disasters.

iv) Failure or damage caused by the use of the inverter and digital encoder option 

for any purpose or application other than the intended one.

4. All expenses incurred by Toshiba for on-site services shall be charged to the 

customer, unless a service contract is signed beforehand between the customer 
and Toshiba, in which case the service contract has priority over this warranty.

Wiring

Mounting and removing

Outline drawing and terminals

1)

2)

The option should be inserted until 
the body is totally covered by the 
slot. (Refer to the picture above)

Insert the option into the 

slot B

 straightly 

and slowly. Keep the option from hitting 
other parts near slot.

1)

Remove the option in the direction of arrow while 
pushing the "PUSH" tab by a screw driver.

Tab for release option

Terminal connector
(D subminiature connector: DE-15 / HD15)

Connector (to inverter)

Product Specification

Item

Specification

Type form

VEC008Z

Product name

Digital Encoder

Function

PG feedback interface (Line driver type)

Applicable encoder

Incremental rotary encoder with differential line driver 
(TIA/EIA RS422) output

Pulse frequency

300kHz or less (Duty: 50% +/- 10%)

Power supply voltage 
for encoder
(Open circuit voltage)

Pin3 (24V): 24V +10%/-15%
Pin7 (12V): 12V +/-5%
Pin15 (5V): 5.2V +/-5%

Maximum load of 
power supply for 
encoder

Pin3 (24V): 100mA
Pin7 (12V): 100mA
Pin15 (5V): 250mA

Recommended cable

Multi-layer shielded cable
Size:

0.25 mm

2

 (AWG26) for signal line

0.5mm

2

 (AWG20) for power supply

Length: 100m or less

Connector

D subminiature connector (DE-15 / HD15)

Applicable model

VF-AS3
(Applicable on slot B)

Operation 
Environment

Operating temperature: -10 to 50°C (Inverter operating 
temperature), in accordance with inverter for other 
environment.

Storage temperature

-25 to 70°C

Warranty

©Toshiba Schneider Inverter Corporation 2016

Содержание VEC008Z

Страница 1: ...the power immediately in case of abnormalities such as smoke abnormal odor noise or blind display Neglect of these conditions can result in fire For repairs call your Toshiba distributor Operate under the environmental conditions prescribed in this manual Operations under any other condition can result in malfunction CAUTION Prohibited If you dispose of the option have it done by a specialist in i...

Страница 2: ...nual This can result in damage or accident Interface connector No Symbol Input output Function Electrical specifications Internal circuit 1 A Input Phase A PG feedback TIA EIA RS422 Termination 120Ω Refer to a 2 NA Input 3 PGVC 24V Output Power supply for encoder DC 24V 10 15 100mA Refer to b 4 reserved 5 6 don t use 7 PGVC 12V Output Power supply for encoder DC 12V 5 100mA Refer to b 8 PGCC Commo...

Страница 3: ... PGCC The cable length is 100m at maximum At that time supply voltage drop by wire impedance should be taken into account Mounting Removing Outline drawing Wiring Mounting and removing Outline drawing and terminals 1 2 The option should be inserted until the body is totally covered by the slot Refer to the picture above Insert the option into the slot B straightly and slowly Keep the option from h...

Страница 4: ...er than the intended one 4 All expenses incurred by Toshiba for on site services shall be charged to the customer unless a service contract is signed beforehand between the customer and Toshiba in which case the service contract has priority over this warranty Product Specification Item Specification Type form VEC008Z Product name Digital Encoder Function PG feedback interface Line driver type App...