E6582062
6. [Advanced] How to use parameters
6-108
4
4
6
9
6. 27. 1 Setting Acc/Dec patterns
<F502: Acc/Dec pattern 1>
<F506: S-Pattern range at Acc start>
<F507: S-Pattern range at Acc completion>
<F508: S-Pattern range at Dec completion>
<F509: S-Pattern range at Dec start>
■
Function
You can select acceleration/deceleration patterns suitable for the purpose.
■
Parameter setting
■
How to select the setting value for <F502>
0: Linear pattern
This is linear acceleration and deceleration, and is a normal Acc/Dec pattern.
Normally, you can use this setting for operation.
6. 27 Switching multiple acceleration/
deceleration
Title
Parameter name
Adjustment range
Unit
Default setting
F502
Acc/Dec pattern 1
0: Linear
1: S-Pattern 1
2: S-Pattern 2
0
F506
S-Pattern range at Acc
start
0-50
%
10
F507
S-Pattern range at Acc
completion
0-50
%
10
F508
S-Pattern range at Dec
completion
0-50
%
10
F509
S-Pattern range at Dec
start
0-50
%
10
1: S-Pattern 1
2: S-Pattern 2
0.0Hz
STOP
13:49
0: Linear
F502 : Acc/Dec pattern 1