2.3 Power Supply Troubleshooting
2 Troubleshooting Procedures
Satellite A50S/TECRA A3X Maintenance Manual (960-534) [CONFIDENTIAL]
2-9
DC power supply (AC adapter)
Error code
Meaning
10h
AC Adapter output voltage is over 16.5V.
11h
Common Dock output voltage is over 16.5V.
12h
Current from the DC power supply is over 7.00A.
13h
Current from the DC power supply is over 0.5A when there is no load.
14h
Abnormal current has been sensed.
Main Battery
Error code
Meaning
22h
Main battery discharge current is over 0.5A when there is no load.
23h
Main battery charge current is over 3.9A when AC adapter is not
connected.
24h
Abnormal current has been sensed.
25h
Main battery charge current is over 0.3A.
Second Battery
Error code
Meaning
32h
Second battery discharge current is over 0.5A when there is no load.
33h
Second battery charge current is over 3.9A. when AC adapter is not
connected.
34h
Abnormal current has been sensed.
35h
Second battery charge current is over 0.3A.
S3V output (P60)
Error code
Meaning
40h
S3V voltage is 3.47V or less when the computer is powered on/off.
45h
S3V voltage is 3.14V or less when the computer is powered on.
46h
S3V voltage is 3.14V or less when the computer is booting up.(CV
support)
Содержание Tecra A3X
Страница 10: ...x CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Страница 12: ...1 Hardware Overview 1 ii CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 1 Hardware Overview ...
Страница 16: ...1 Hardware Overview 1 vi CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 50: ...1 Hardware Overview 1 13 AC Adapter 1 34 CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 51: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Страница 52: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 2 ...
Страница 56: ...2 Troubleshooting Procedures 2 vi CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 105: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Страница 106: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 3 ...
Страница 110: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 217: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Страница 218: ...4 Replacement Procedures 4 ii CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 4 ...
Страница 336: ...Replacement Procedures 4 23 Fluorescent Lamp 4 114 CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 337: ... CONFIDENTIAL Appendices ...
Страница 338: ...Appendices App ii CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 350: ...Appendices Appendix A Handling the LCD Module A 6 CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 392: ...Appendices Appendix C Pin Assignment C 34 CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 402: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 404: ...Appendices Appendix F Wiring Diagrams F 2 CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 406: ...Appendices Appendix G BIOS KBC EC Update G 2 CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Страница 408: ...Appendices Appendix H Reliability H 2 CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...