(TURBO) Button

Control the Turbo speed. Press to select either 
Turbo or normal fan speed. Set the Turbo control 
to high for maximum moisture removal. When 
room humidity is at your preferred level, it is 

  Turbo speed.

(TIMER) Button

Starts the Timer ON and Timer OFF function setting.

Up/Down Buttons (  /  )

•  Humidity Set Control Buttons

The humidity level can be set within a range 
of 35% RH (Relative Humidity) to 85% RH 
(Relative Humidity) in 5% increments.
For drier air, press the   button and set to a 
lower value (%).
For damper air, press the   button and set a 
higher value (%).

•  TIMER Set Control Buttons

Use the   and   key buttons to set the Timer 
ON or Timer OFF from 0 to 24 hours.

Button

 .

LED Display

Shows the set % humidity level from 35% to 85% 
or auto start/stop time (0 ~ 24) while setting, 
then shows the actual (+/- 5% accuracy) room 
% humidity level in a range of 30% RH (Relative 
Humidity) to 90% RH (Relative Humidity).

Error Codes and Protection Code:

AS

  

-  Humidity sensor error - Unplug the unit 

and plug it back in. If error persists, contact 
Customer Service.

ES

  

-  Tube Temperature sensor of the evaporator 

error - Unplug the unit and plug it back in. If 
error persists, contact Customer Service.

P2 

 

-  Bucket is full or bucket is not in right 

position - Empty the bucket and replace it 
in the right position. (only available for the 
unit with no pump feature.)

E3

  -  Unit malfunction - Unplug the unit and plug 

it back in. If error persists, contact Customer 
Service.

Eb

  -  Bucket is removed or not in right position - 

Replace the bucket in the right position. (only 
available for the unit with pump feature.)

Bucket Full Light

Lights up when the bucket is ready to be emptied.

Auto Shut Off

  when the bucket is full, 

or when the bucket is removed or not replaced in 
the proper position. When the setting humidity is 

Other Features

Auto Defrost

When frost builds up on the evaporator coils, 

  and Auto Defrost 

function will run automatically.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restarted 

 rst 3 minutes to protect compressor 

operation. The unit will restart automatically after 
3 minutes.

Auto-Restart

If the unit stops unexpectedly due to a power cut, 
it will restart with the previous function setting 
automatically when the power resumes.

reached, the compressor will be shut off 

automatically. The fan motor will continue 

operating additional 3 minutes.

Содержание TDDP7011ES2

Страница 1: ...al carefully and keep it for future reference change without prior notice for product improvement Consult with your dealer or the manufacturer for details version A 10 2017 us toshibalifestyle com TDDP7011ES2 Operating Instructions Installation Instructions Troubleshooting Tips Care and Cleaning ...

Страница 2: ...hen installing operating and maintaining this product User Manual CAUTION Safety Precautions 3 6 Installation Instructions 13 Care and Cleaning 14 Troubleshooting Tips 15 Contact the authorized service technician for repair or maintenance of this unit The unit is not intended for use by young children or persons with reduced physical sensory or mental capabilities without supervision Young childre...

Страница 3: ...and electric shock Ventilate room before operating the unit if there is a gas leak from other appliances Do not operate or stop the unit by inserting or pulling out the power cord plug It may cause electric shock Do not allow water to come into contact with any electric parts It may cause failure or electric shock Do not use the socket if it is loose or damaged re and electric shock Do not use or ...

Страница 4: ...imb up on or sit on the unit You may be injured if you fall or if the unit falls over ngers lter once every two weeks ed service technician ower vases or other water container on top of the unit re the unit and unplug it from the main power supply immediately Visually inspect the unit to ensure there is no damage If you ed technician to avoid damage to the unit due to lightning Do not run cord und...

Страница 5: ... or protected by a time delay fuse or ed electrician install the proper receptacle Ensure the receptacle is accessible after the unit installation Do not use extension cords or an adapter plugs with this unit However if it is er extension cord only available at most local hardware stores To avoid the possibility of personal injury always disconnect the the unit from power supply before installing ...

Страница 6: ...t Power cord buckle placed in the water bucket used only when storing the unit Installed as shown below Re ar F ront Power cord buckle 1 pc Insert the power cord buckle into the unit Fig 1 Fig 2 NOTE All the pictures in this manual are for illustrative purposes only The actual shape of the unit you purchased may be slightly di erent but its operations and function are similar OPERATING INSTRUCTION...

Страница 7: ...COMFORT function is turned on set humidity is automatic and cannot be changed manually FILTER Button This feature is a reminder to clean the Air Filter for more operation The LED light will illuminate after 250 hours of fan motor operation To reset after cleani ter press the Filter button and the light will go o CONTINUE Button Press to activate the continuous dehumidifying operation Comfort dehum...

Страница 8: ...or of the evaporator error Unplug the unit and plug it back in If error persists contact Customer Service P2 Bucket is full or bucket is not in right position Empty the bucket and replace it in the right position only available for the unit with no pump feature E3 Unit malfunction Unplug the unit and plug it back in If error persists contact Customer Service Eb Bucket is removed or not in right po...

Страница 9: ...tart operation when the bucket back in place 1 Pull out the bucket 2 Hold both sides of the bucket evenly and pull it out from the unit Fig 5 Setting the Timer ON and Timer OFF rst press the Timer button the Timer OFF indicator light illuminates It indicates the Timer OFF program is initiated Press it again the Timer ON indicator light illuminates It indicates the Timer ON is initiated rst press t...

Страница 10: ...t 2 Continuous draining oor drain by attaching the unit with a water hose Id Ø 5 16 not included with a female threaded end ID M 1 not included Remove the plastic cover from the back drain outlet of the unit and set aside then insert the drain hose through the oor drain or a suitable drainage facility See Fig 7 and Fig 8 When you remove the plastic cover if there is some water in the back drain ou...

Страница 11: ...n 32 F 0 C otherwise water may become ice causing the water house to be blocked and the unit to stop operating Make sure to empty the bucket at least once a week a week when using the pump draining feature When the pump draining feature is not being used remove the pump drain hose from the outlet Removing Collected Water cont ...

Страница 12: ...residential applications only This dehumidifier should not be used for commercial or industrial applications Place the dehumidifier on a smooth level floor strong enough to support the unit with a full bucket of water Allow at least 8 inches of air space on all sides of the unit for air circulation at least 16 inches for air outlet Place the unit in an area where the temperature will not fall belo...

Страница 13: ...on use a vacuum cleaner or brush to clean 2 Clean the bucket Every few weeks clean the bucket thoroughly to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and mild detergent Swish it around in the bucket empty and rinse 3 Clean the air filter lter outwards See Fig 10 lter with clean water then dry lter replace bucket 4 When not using the unit for long time pe...

Страница 14: ... there are no curtains blinds or furniture blocking the front or back of the er The humidity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 41 F 5 C There is a water vapor source in the room The unit makes a loud noise when operating lter Refer to Care and Cleaning section The unit is tilted instead of upright...