WARNING - Electrical Information

• 

The manufacturer’s nameplate is located on the rear panel of the unit and contains 
electrical and other technical data specifi c to this unit.

• 

Be sure the unit is properly grounded. To minimize shock and fi re hazards, proper 
grounding is important. The power cord is equipped with a three-prong grounding 
plug for protection against shock hazards.

• 

Your unit must be used in a properly grounded wall receptacle. If the wall receptacle 
you intend to use is not adequately grounded or protected by a time delay fuse or 
circuit breaker, have a qualifi ed electrician install the proper receptacle.

• 

Ensure the receptacle is accessible after the unit installation.

• 

Do not use extension cords or an adapter plugs with this unit. However, if it is 
necessary to use an extension cord, use an approved “dehumidifi er” extension cord 
only (available at most local hardware stores).

• 

To avoid the possibility of personal injury, always disconnect the the unit from power 
supply, before installing and/or servicing.

WARNING - For your safety

• 

Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of 
this or any other appliance.

• Avoid 

fi re hazard or electric shock. Do not use an extension cord or an adaptor plug. 

Do not remove any prong from the power cord.

Содержание TDDP2012ES2

Страница 1: ...P3512ES2 TDDP5012ES2 TDDP5012ES2P Warning notices Before using this product please read this manual carefully and keep it for future reference change without prior notice for product improvement Consult with your dealer or the manufacturer for details m o c e l y t s e f i l a b i h s o t s u 9 1 0 2 1 0 B n o i s r e v Sa O In Ca Tr ...

Страница 2: ...installing operating and maintaining this product User Manual CAUTION Safety Precautions 3 Operating Instructions 6 Installation Instructions 12 Care and Cleaning 13 Troubleshooting Tips 14 Contact an authorized service technician for repair or maintenance of this unit The unit is not intended for use by young children or persons with reduced physical sensory or mental capabilities without supervi...

Страница 3: ...e room before operating the unit if there is a gas leak from other appliances Do not operate or stop the unit by inserting or pulling out the power cord plug It may cause electric shock Do not allow water to come into contact with any electric parts It may cause failure or electric shock Do not use the wall outlet if it is loose or damaged It may cause fire and electric shock Do not use or keep th...

Страница 4: ... securely and take caution to avoid injuries to hand and fingers Clean filter once every two weeks If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flower vases or other water containers on top of the unit Water may spill inside the unit causing insulation failure and electrical shock or fire If the unit is knocked over during ...

Страница 5: ... a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Ensure the receptacle is accessible after the unit installation Do not use extension cords or an adapter plugs with this unit However if it is necessary to use an extension cord use an approved dehumidifier extension cord only available at most local hardware stores To avoid the possibility of personal...

Страница 6: ...the water bucket used only when storing the unit Installed as shown below Re ar Front Power cord buckle 1 pc Insert the power cord buckle into the unit Fig 1 Fig 2 NOTE All the pictures in this manual are for illustrative purposes only The actual shape of the unit erent but its operations and fuctions are similar OPERATING INSTRUCTIONS Operating Instructions pump drain hose 1pc only for the unit w...

Страница 7: ...Pumpmodelsonly Press to activate the pump operation NOTE Make sure the pump drain hose is installed into the unit and the continuous drain hose is removed from the unit before the pump operation is activated When the bucket is full the pump starts to work Refer to the next pages for removing the collected water Do not use this operation when the outdoor temperature is equel to or less than 0ºC 32º...

Страница 8: ...ice ES Tube Temperature sensor of the evaporator error Unplug the unit and plug it back in If error persists contact Customer Service P2 Bucket is full or bucket is not in right position Empty the bucket and replace it in the right position only available for the unit with no pump feature Eb Bucket is removed or not in right position Replace the bucket in the right position only available for the ...

Страница 9: ...cket back in place 1 Pull out the bucket 2 Hold both sides of the bucket evenly and pull it out from the unit Fig 5 Setting the Timer ON and Timer OFF When the unit is on first press the Timer button the Timer OFF indicator light illuminates It indicates the Timer OFF program is initiated Press it again the Timer ON indicator light illuminates It indicates the Timer ON is initiated When the unit i...

Страница 10: ... included Remove the plastic cover from the back drain outlet of the unit and set aside then insert the drain hose through the oor drain or a suitable drainage facility See Fig 7 and Fig 8 When you remove the plastic cover if there is some water in the back drain outlet of the unit you must dry it Make sure the hose is secure so there are no leaks and the end of the ow Direct the hose toward the d...

Страница 11: ...e turn off the unit and plug the power cord out Check the following things Cleaning the filter of the pump Remove the bucket from the unit take down the pump and clean the filter of the pump Check that the pump drain hose does not link or block Empty the water of the bucket Reinstall the pump hose if it drops and reinstall the bucket properly Turn on the unit If the error repeats call for service ...

Страница 12: ...ns only This for commercial or industrial applications Place the on a smooth level rong enough to support the unit with a full bucket of water Allow at least 8 inches of air space on all sides of the unit for air circulation at least 16 inches for air outlet This unit is designed to operate with a working environment between 41 F 5 C and 90 F 32 C and between 30 RH and 80 RH The coils can become c...

Страница 13: ...lean the bucket Every few weeks clean the bucket thoroughly to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and mild detergent Swish it around in the bucket empty and rinse 3 Clean the air filter To remove the filter pull filter outwards See Fig 10 Wash the filter with clean water then dry Re install the filter replace bucket 4 When not using the unit for l...

Страница 14: ...or furniture blocking the front or back of the dehumidifier The humidity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 41 F 5 C There is a water vapor source in the room The unit makes a loud noise when operating Air filter may be dirty Clean filter Refer to Care and Cleaning section The unit is tilted instea...

Страница 15: ......

Страница 16: ......

Отзывы: