Installation of 3DW Diffusor

WARNING

Please install the 3DW Diffusor in a position that can fully bear the load. If the strength is insufficient, the 3DW Diffusor may 
fall and cause injury.

Please wear safety helmet to prevent head injuries caused by falling objects. 

When installing the air duct, if the air duct passes through the fire-resistant area, please use the air duct with flame 
retardant material, and install fire and disaster prevention dampers. 
Otherwise, there is a risk of spread in case of fire.

REQUIREMENT

To prevent damage to the 3DW Diffusor and personal injury, be sure to follow the following instructions.

Do not step on the package of the 3DW Diffusor or place any heavy objects on it. 

Do not place the panel assembly face down or on bumps.

Please handle the 3DW Diffusor together with its package. In case of inevitable handling without package, please use 
cushion cloth to prevent scratches.

When handling the 3DW Diffusor, please hold the outside of the front panel assembly to avoid stress on other parts 
(horizontal louver, vertical louver, connectors).

Direct connection: if D = 91 or 91 < D ≤ 101

Installing the mounting frame

Before installing the indoor unit, secure the mounting frame. 

Fix the mounting frame to the indoor unit using the fixing screws (3) (M4x8) for mounting frame.

* Only 12 places on TCB-TDL0141SDY-C need to be fixed, meaning there will be 4 fixing screws for mounting frame (3) left.

(3) Fixing screw for mounting frame

(2) Mounting frame

Indoor unit

Sticking sponge on mounting frame

Please stick 2 pieces of sponge (5) and 2 pieces of sponge (6) that are attached with the machine to the fixed screws for 
mounting frame (3).

Please stick the attached sponge (7) onto the above sponges, the sponge (7) on the left and right sides can be directly 
stuck, and cut the remaining sponge (7) according to the actual length and stick it onto the top and bottom of the mounting 
frame. (There are enough sponges (7), please cut and use it according to the actual situation.)

Please stick the sponge (8) positioning against the indoor unit to a place which is between the tips of the fixing screws (3) 
emerged from the inside of the mounting frame (2).

CAUTION

When sticking a sponge, press it carefully to ensure that there is no clearance or loosening, and no sheet metal is exposed. 
Otherwise, it may cause condensation and dirt on the ceiling.

š⎭㔫

š⎭㔫

(3) Tips of the  fixing screws for 

mounting frame

(7) Sponge
(Do not cut the sponge on the 
side, dimension 500×60×6)

(6) Sponge

Indoor unit

(7) Sponge
(Do not cut the sponge on the side, 
dimension 500×60×6)

(7) Sponge
(Cut the extra part based on the actual situation)

(6) Sponge

(5) Sponge

(5) Sponge

(8) Sponge

(7) Sponge
(Cut the extra part based 
on the actual situation)

(5) Sponge

(8) Sponge

Stick sponge after it fits with 
the indoor unit

(7) Sponge

(7) Sponge

Stick sponge after it fits with 
the indoor unit

(2) Mounting frame

EN-7

EN-8

Содержание TCB-TDL0141SDY-E

Страница 1: ...s Ελληνικα Svenska Suomi Norsk Dansk Română Български Eesti Latviski Slovenčina Slovenščina AIR CONDITIONER ACCESSORY Installation Manual 3DW Diffusor Model name TCB TDL0141SDY E TCB TDL0181SDY E TCB TDL0271SDY E TCB TDL0141SDY TR TCB TDL0181SDY TR TCB TDL0271SDY TR For commercial use Ticari kullanım için ...

Страница 2: ...ctions may result in drop noise vibration water leakage and other problems Only a qualified installer or qualified service person is allowed to carry out the installation work Improper installation may result in water leakage electric shock fire and other problems Before the installation maintenance repair or removal work please set the circuit breaker to the OFF position otherwise there is a risk...

Страница 3: ...ulation sponge Inside heat insulation for mounting frame 190 33 6 1 3 Fixing screw for mounting frame M4x8 16 9 Wire clip 1 10 Binding belt 2 4 Fixing screw for front panel assembly M4x25 6 11 Owner s manual 1 12 Installation manual this manual 1 4 Part Names 5 Dimension Unit mm Horizontal louver swing up and down Vertical louver swing left and right Panel 34 5 11 80 5 7 5 21 6 61 180 94 42 Distan...

Страница 4: ...door 3 Kitchen 4 A place where the 3DW Diffusor is exposed to the outdoor air directly In the above places please paste heat insulation materials such as sponges on the panel and the horizontal louver of 3DW Diffusor that are exposed to high humidity air Reference Test conditions for condensation Indoor Dry ball temperature 27 C Wet ball temperature 24 C Air volume Low Running time 4 hours 7 Space...

Страница 5: ... frame Only 12 places on TCB TDL0141SDY C need to be fixed meaning there will be 4 fixing screws for mounting frame 3 left 3 Fixing screw for mounting frame 2 Mounting frame Indoor unit Sticking sponge on mounting frame Please stick 2 pieces of sponge 5 and 2 pieces of sponge 6 that are attached with the machine to the fixed screws for mounting frame 3 Please stick the attached sponge 7 onto the a...

Страница 6: ...g and fix the mounting frame with screws Please install the indoor unit and connect the pipelines Perform the heat insulation treatment on the refrigerant connecting pipe and drainage pipe For details refer to the installation manual of the indoor unit Please make the drill on the wall according to Drilling on the wall Please refer to the figure below to install the wooden frame locally purchased ...

Страница 7: ...cting wire of the front panel assembly 1 to the wall opening and then push the front panel assembly 1 into the opening Temporarily fix two screws at the central part of the panel assembly 1 with the complimentary fixing screws for panel assembly M4x25 4 Similarly after temporarily fixing the remaining 4 screws tighten all the screws 6 in total Pay attention to the tightening sequence of the screws...

Страница 8: ... drainpipe Side cover of PCB board Plug of PCB board Plug the connector of the wire into the PCB board socket CN510 white To protect the PCB board from the external pressure fix the connecting wire on a wire clip on the back of the side cover of the PCB board about 100 mm away from the plug with the binding belt 10 Close the side cover of the PCB board and fix it with 2 screws Tidy wires Tidy the ...

Страница 9: ...l static pressure Please refer to the installation manual of indoor unit for the setting method of external static pressure The pressure loss characteristics of 3DW Diffusor will affect the external static pressure Please refer to the attached fan characteristics for details To avoid deviation from the operating range please adjust the air volume by adjusting the air doors set at the suction and a...

Страница 10: ...door unit before the trial operation of the 3DW Diffusor For details refer to the installation manual of the indoor unit Please control the operation of the horizontal louver and vertical louver by the remote controller and confirm that the movement and sound are normal Refer to the manual of the remote controller for operation The clearance on the right side of the horizontal louver must be even ...

Страница 11: ...35 200 300 400 500 600 700 Static Pressure Pa Blowing downward Blowing horizontally Low 20 Pa Low 10 Pa High 20 Pa High 10 Pa 0 5 10 15 20 25 30 35 40 400 500 600 700 800 900 1000 Static Pressure Pa Blowing downward Blowing horizontally Low 20 Pa Low 10 Pa High 20 Pa High 10 Pa 0 5 10 15 20 25 30 35 40 400 500 600 700 800 900 1000 Static Pressure Pa Blowing downward Blowing horizontally Low 20 Pa ...

Страница 12: ...D0X7203601 00 ...

Отзывы: