27/29
SD-R5112 Rev.1.0
13.Safety Standards/Agency Approvals
(1) Safety
EN60950
UL 1950
CAN/CSA-22.2 No.950
(2) Laser
FDA 21CFR (U.S.A./DHHS)
EN60825-1 (Europe)
(3) EMC
CE
EN50081-1
: 1992 [Residental, commercial & light industry]
EN55022
: 1998 [Class B]
A1
: 1998+2001 [Information Technology equipment-
Immunity characteristices Limits and
methods of masurement]
IEC61000-4-2+A1 : 1995+1998 [CD:4 kV, ID: 4 kV, AD:8 kV]
IEC61000-4-3+A1 : 1995+1998 [3 V/m, 80-1000 MHz,
1 kHz 80 % AM ]
IEC61000-4-4
: 1995 [AC-line: 1 kV, I/F 0.5 kV
f: 5 kHz, Polarity: +/-]
IEC61000-4-5
: 1995 [AC-line: 2 kV/1 kV, Polarity: +/-]
IEC61000-4-6
: 1996 [3 V, 0.15-80 MHz, 80 % AM]
IEC61000-4-8
: 1993 [1 A/m, 50 Hz]
IEC61000-4-11
: 1994 [>95 % 0.5, 30% 25, >95 250]
TAIWAN EMI
CNS 13438
14. Electrostatic Discharge
Standard
IEC61000-4-2
(1) Operating (Read)
8 kV or less
(2) Operating (Write)
8 kV or less
(3) Damage including
15 kV or more
15. Accessories
1-Short Jumper
(installed in'MA' header)
1-Safety Instruction Manual
16. Packaging
(1) 15 unit in a bulk package
24 bulk packs on one pallet.
*All transportation is allowed with pallet.
(Transportation with bulk package is not allowed.)
(1) 10 unit in a bulk package
28 bulk packs on one pallet.
*All transportation is allowed with pallet.
(Transportation with bulk package is allowed.)
17. CE Declaration of conformity