25/28
SD-M1212 Rev.1.0
11.Connection
11.1. Power Supply Cable
(1) Housing
AMP JAPAN P/N 1-480424-0 or equivalent
(2) Contact
AMP JAPAN P/N 170148-2 or equivalent
(3) Cable Length
AWG 28
Max. 2 m
11.2. Interface Cable
(1) Connector
ATAPI specification
(2) Cable
40 core type
Specific Impedance
100 OHM +/-10 % (without shield)
Length
Max. of 0.46 m for total ATAPI bus length
11.3. Audio Cable
Unbalanced and shielded
(1) Capacitance
Less than 1000 pF
(2) Length
Max. 3 m
12.Emergency Eject
Execute following procedure only in the case of emergency (Tray will not eject and disc
can not be removed although pressing Eject Button).
(1) Turn the drive supplying power off.
(2) Insert solid bar (like paper clip) into Emergency Eject hole and push as shown in Fig.20.
Then Tray will be ejected.
(3) After removed the disc, gently push Tray to close.
diameter 1.0 to 1.5 mm
50 mm
Figurer 20 Insert the bar