3.28 LAN/Modem/Bluetooth/IEEE1394 Test Program
3 Tests and Diagnostics
TECRA A8 /Satellite Pro A120 Maintenance Manual (960-573)
[CONFIDENTIAL]
3-77
Table 3-6 Error code for Bluetooth test (BD_ADDR) (2/2)
Error code
Meaning
0x20
Unsupported LMP Parameter Value.
0x21
Role Change Not Allowed.
0x22
LMP Response Timeout.
0x23
LMP Error Transaction Collision.
0x24
LMP PDU Not Allowed.
0x25
Not Exist
0x26
Not Exist
0x27
Not Exist
0x28
Not Exist
0x29
Not Exist
0x2a
Not Exist
0x2b
Not Exist
0x2c
Not Exist
0x2d
Not Exist
0x2e
Not Exist
0x2f
Not Exist
See the Specification of the Bluetooth System in detail.
Subtest03
Communication tests (DUT mode)
This subtest checks the Bluetooth communication functions. Preparing the tester machine for
the Bluetooth test program. Insert a floppy disk containing the test program into the tester
machine and turn on the tester machine. The Bluetooth test menu will appear:
Press
3
to select the test and press
Enter
in the target machine. The following message will
appear:
When the test begins, the machine displays
BD_ADDR of the DUT
. The progress bar
stops when the test is completed. The following message is displayed.
-----------------------------------------------------------------------------
Bluetooth Subsystem T&D for PCSE(CS-Air) VerX.XX Copyright (C) by TOSHIBA Co.
-----------------------------------------------------------------------------
+----------------------+
| DUT | BD_ADDR of the DUT = XXXXXXXXXXXXX [h]
+----------------------+
Ready>>>>>>>>>>>>>>>>>>>>>> <-
Progress Bar
[ESC] : Stop
Содержание Satellite Pro A120
Страница 10: ...x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Страница 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 45: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Страница 46: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 129: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Страница 130: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 3 ...
Страница 134: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 241: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Страница 242: ...4 Replacement Procedures 4 ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 246: ...4 Replacement Procedures 4 vi CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 337: ... CONFIDENTIAL Appendices ...
Страница 338: ...Appendices App ii CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 346: ...Appendices App x CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 352: ...Appendices Appendix A Handling the LCD Module A 6 CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 360: ...Appendices Appendix B Board Layout B 8 CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 418: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 422: ...Appendices Appendix F Wiring diagrams F 4 CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 424: ...Appendices Appendix G BIOS rewrite procedures G 2 CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 426: ...Appendices Appendix H EC KBC rewrite procedures H 2 CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...
Страница 428: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL TECRA A8 Satellite Pro A120 Maintenance Manual 960 573 ...