2 Troubleshooting Procedures
Procedure 2
Connector and Replacement Check
The connection of cable and board may be defective. Otherwise, they may be faulty.
Disassemble the computer following the steps described in Chapter 4,
Replacement
Procedures
, and perform the following checks:
Check 1
Make sure keyboard cable is firmly connected to system board.
If the connection is loose, reconnect firmly and repeat Procedure 1. If the problem
still occurs, go to Check 2.
Check 2
Keyboard may be faulty. Replace it with a new one following the instructions in
Chapter 4,
Replacement Procedures
. If the problem still occurs, perform Check 3.
Check 3
System board may be faulty. Replace it with a new one following the instructions
in Chapter 4,
Replacement Procedures
.
30
Satellite P500 and Satellite Pro500
Maintenance Manual (960-Q08)
Содержание Satellite P500
Страница 14: ...Satellite P500 and Satellite Pro500 Maintenance Manual 960 Q08 ...
Страница 15: ...Satellite P500 and Satellite Pro500 Maintenance Manual 960 Q08 Chapter 1 Hardware Overview ...
Страница 46: ...2 1 Satellite P500 and Satellite Pro500 Maintenance Manual 960 Q08 Chapter 2 Troubleshooting Procedures ...
Страница 47: ...2 2 Satellite P500 and Satellite Pro500 Maintenance Manual 960 Q08 ...
Страница 90: ...Troubleshooting Procedures Satellite P500 Maintenance Manual 960 Q08 41 ...
Страница 115: ...Test Program for Field 18 Satellite P500 and Satellite Pro P500 Tests and Diagnostics Manual ...
Страница 230: ...Satellite P500 and Satellite Pro500 Maintenance Manual 960 Q08 i Appendices ...
Страница 231: ...Satellite P500 and Satellite Pro500 Maintenance Manual 960 Q08 ii ...
Страница 246: ...Board Layout Satellite P500 and Satellite Pro500 Maintenance Manual 960 Q08 B 7 02 CN1 TP Board to M B CONN ...
Страница 284: ...Wiring Diagrams Satellite P500 and Satellite Pro500 Maintenance Manual 960 Q08 F 2 ...
Страница 288: ...Reliability Satellite P500 and Satellite Pro500 Maintenance Manual 960 Q08 ...