2.5 2.5-inch HDD
2 Troubleshooting
Satellite L300D/L305D/Satellite Pro L300D/EQUIUM L300D/SATEGO L300D
Maintenance Manual
2-13
Procedure 4 Test Program Check
Run the HDD test program stored on the maintenance test program disk for all test items.
See Chapter 3 for details on how to use the test program.
If an error is detected during the HDD test, an error code and status will be displayed. The
error codes and their status names are listed in Table 2-1. If an error code is not generated
and the problem still exists, go to Procedure 5.
Table 2- 1 HDD Error Code and Status
Code
Status
1
Get Parameter Fail !
2
Read Old Data Error
3
Write Pattern Error
4
Read Back Data Error
5
Data Compare Error
6
Restore Data Error
7
Read Verify Error
9
Seek Error
10
Disk Controller Self Test Failed
11
Disk Controller Test unexpected interrupt Failed
12
Disk Controller action Test Failed
13
Disk dos not support SMART
14
Disk read attribute threshold error
15
Disk read attribute value error
16
Disk SMART attribute value error
Downloaded from LpManual.com Manuals