2.2 Troubleshooting Flowchart
2 Troubleshooting Procedures
If the diagnostics program cannot detect an error, the problem may be intermittent. The
Running Test program should be executed several times to isolate the problem. Check the
Log Utilities function to confirm which diagnostic test detected an error, then perform the
appropriate troubleshooting procedures as follows:
1.
If an error is detected on the system test, memory test, real timer test, perform the
System Board and Processor Module Troubleshooting Procedures in Section 2.4.
2.
If an error is detected on the floppy disk test, perform the FDD Troubleshooting
Procedures in Section 2.5.
3.
If an error is detected on the hard disk test, perform the HDD Troubleshooting
Procedures in Section 2.6.
4.
If an error is detected on the keyboard test, perform the Keyboard Troubleshooting
Procedures in Section 2.7.
5.
If an error is detected on the display test, perform the Display Troubleshooting
Procedures in Section 2.8.
6.
If an error is detected on the Optical Drive test, perform the Optical Drive
Troubleshooting Procedures in Section 2.9.
7.
If an error is detected on the modem test, perform the Modem Troubleshooting
Procedures in Section 2.10.
8.
If an error is detected on the LAN test, perform the LAN Troubleshooting Procedures
in Section 2.11.
9.
If an error is detected on the Wireless LAN test, perform the Wireless LAN
Troubleshooting Procedures in Section 2.12.
10.
If an error is detected on the sound test, perform the Sound Troubleshooting
Procedures in Section 2.13.
11.
If an error is detected on the SD card test, perform the SD card slot Troubleshooting
Procedures in Section 2.14.
Satellite A40 Maintenance Manual (960-458)
2-5
Содержание Satellite A40 Series
Страница 10: ...x Satellite A40 Maintenance Manual 960 458 ...
Страница 11: ...Chapter 1 Hardware Overview ...
Страница 12: ...1 Hardware Overview 1 ii Satellite A40 Maintenance Manual 960 458 ...
Страница 51: ...Chapter 2 Troubleshooting Procedures ...
Страница 52: ...2 Troubleshooting Procedures 2 ii Satellite A40 Maintenance Manual 960 458 ...
Страница 56: ...2 Troubleshooting Procedures 2 vi Satellite A40 Maintenance Manual 960 458 ...
Страница 117: ...2 14 SD Card Slot Troubleshooting 2 Troubleshooting Procedures Satellite A40 Maintenance Manual 960 458 2 61 ...
Страница 118: ...Chapter 3 Tests and Diagnostics ...
Страница 119: ...3 Tests and Diagnostics 3 ii Satellite A40 Maintenance Manual 960 458 ...
Страница 203: ...3 Tests and Diagnostics 3 29 Thermal Radiation Control Test 3 82 Satellite A40 Maintenance Manual 960 458 ...
Страница 204: ...Chapter 4 Replacement Procedures ...
Страница 205: ...4 Replacement Procedures 4 ii Satellite A40 Maintenance Manual 960 458 ...
Страница 358: ...Appendices ...
Страница 359: ...Appendices App ii Satellite A40 Maintenance Manual 960 458 ...
Страница 365: ...Appendices App viii Satellite A40 Maintenance Manual 960 458 ...
Страница 371: ...Appendices Appendix A Handling the LCD Module A 6 Satellite A40 Maintenance Manual 960 458 ...
Страница 411: ...Appendices Appendix E Key Layout E 4 Satellite A40 Maintenance Manual 960 458 ...
Страница 413: ...Appendices Appendix F Wiring Diagrams F 2 Satellite A40 Maintenance Manual 960 458 ...
Страница 415: ...Appendices Appendix G BIOS Rewrite Procedures G 2 Satellite A40 Maintenance Manual 960 458 ...
Страница 417: ...Appendices Appendix H EC KBC Rewrite Procedures H 2 Satellite A40 Maintenance Manual 960 458 ...
Страница 419: ...Appendices Appendix I Reliability I 2 Satellite A40 Maintenance Manual 960 458 ...