– 11 –
Installation Manual
Monitor screen
Check the current usage status.
NOTE
Total running hour
• The Total running hour is recorded on the remote controller.
• The time is not recorded during Self cleaning operation or fan operation.
Outdoor temp.
• Displays the temperature around the vent of the outdoor unit.
• The displayed temperature may differ from the actual outdoor temperature.
Others
• The Header status appears during group connection.
• The screen returns to the previous display if no operation is performed for 60 seconds.
1
Push [
MONITOR] button.
The monitor screen appears.
2
Push [
CANCEL] button to return.
(1) Displays the set temperature.
(2) Displays the temperature measured by the indoor
temperature sensor of the indoor unit.
If the sensor is set to that of the remote controller,
the temperature measured by the remote controller
sensor is displayed.
(3) Displays the temperature around the vent of the
outdoor unit.
(4) Displays the remaining time until the filter sign lights
up.
(5) Displays the accumulated operating time.
24
Room A
12:00
Mode
Fan Speed
Cool
Set temp.
24°C
24°C
35°C
2500
10480
Indoor temp.
Outdoor temp.
Filter remaining hour
Total running hour
Monitor
Return
(1)
(2)
(3)
(4)
(5)
Содержание RBC-AMS54E