background image

12

Heating capacity

If the outdoor temperature is too low, it is recommended that additional heating appliances be used in con-
junction with the air conditioner.

Power failure

Power failure during operation will stop the unit completely.

• The OPERATION lamp (green) on the indoor unit will start flashing when power is restored.

• To restart operation, push the START/STOP button on the remote controller.

Air conditioner operating conditions

For proper performance, operate the air conditioner in the following temperature conditions:

If air conditioner is used outside of the above conditions, safety protection may work.

Cooling

Outdoor temperature

: –5°C to 43°C

operation

Room temperature

:  18°C to 32°C

CAUTION

Room relative humidity – less than 80 %.  If the air conditioner operates
in excess of this figure, the surface of the air conditioner may cause dewing.

Heating

Outdoor temperature

: –15°C to 21°C

operation

Room temperature

: Less than 30°C

PROBLEMS AND CAUSES

CAUTION

If any of the following conditions occur, turn off the main power supply switch and immediately contact the
dealer :

• The indicator lamps flash at short intervals (5 Hz) even though you have tried turning off the power

supply and turning on again after 2 to 3 minutes.

• Switch operation is erratic.

• The main power fuse often blows out, or the circuit breaker is often activated.

• A foreign matter or water has fallen into the inside of the air conditioner.

• Any other unusual condition is observed.

Before you ask for servicing or repairs, check the following points.

Recheck

Inoperative

• The main power switch is turned off.
• The circuit breaker is activated to cut off power supply.
• The main power fuse is blown.
• ON timer is set.

Does not cool well or heat well

• The air inlet or outlet of the outdoor unit is blocked.
• Doors or windows are opened.
• The air filter is blocked with dust.
• The louver is not at the correct position.
• The fan speed is set too low.
• The set temperature is too high. (In cooling operation)
• The set temperature is too low. (In heating operation)

Содержание RAV-SM560AT-E

Страница 1: ... Installateur oder vom Lieferanten aushändigen Eine Bitte an den Installateur oder Lieferanten Bitte erklären Sie dem Käufer den Inhalt der Betriebsanleitung und händigen sie ihm aus Grazie di aver acquistato un condizionatore d aria TOSHIBA Prima di usare il condizionatore d aria leggere con attenzione questo manuale del proprietario Si raccomanda di tenere a portata di mano il Manuale del propri...

Страница 2: ...gerante convenzionale R22 per prevenire la distruzione dello strato di ozono dell atmosfera terrestre ADOPCIÓN DE NUEVO REFRIGERANTE Este aparato de aire acondicionado es un modelo reciente que incorpora el nuevo refrigerante HFC R410A en lugar del refrigerante convencional R22 para así evitar daños en la capa de ozono ADOPÇÃO DO NOVO REFRIGERANTE Este ar condicionado é um modelo novo que adopta u...

Страница 3: ...CESORIOS 49 PRECAUCIONES PARA SU SEGURIDAD 49 NOMBRE DE LOS COMPONENTES 51 NOMBREY FUNCIONES DE LOS INDICADORESY DE LOS CONTROLES 51 NOMBREY FUNCIONES DE LOS INDICADORESY DE LOS CONTROLES 52 UTILIZACIÓN CORRECTA 54 FUNCIONAMIENTO CON AIRE SECO 55 ACESSÓRIOS 61 PRECAUÇÕES DE SEGURANÇA 61 NOME DAS PEÇAS 63 NOME E FUNÇÕES DOS INDICADORES E CONTROLOS 63 NOME E OPERAÇÕES DOS INDICADORES E CONTROLOS 64 ...

Страница 4: ...ce person and not for the customer Avoid cooling the room too strong or exposing the human body to cool breeze for a long time as it is bad for the health When you notice something abnormal with the air conditioner smells like some thing scorching poor cooling etc immediately turn off the main switch the circuit breaker from the mains to stop the air conditioner and contact the dealer If the air c...

Страница 5: ...the room Poor ventilation causes oxygen shortage Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner otherwise it may cause imperfect combustion When the air conditioner is used in a closed room be careful of sufficient ventilation of the room Poor ventilation causes oxygen shortage Do not touch any switches with wet finger otherwise you may...

Страница 6: ...n operation the OPERATION lamp is orange TEMPORARY button If you misplace or lose the remote controller or its batteries are exhausted push the TEMPORARY button 1 Open the air inlet grille to push theTEMPORARY button 2 Push the TEMPORARY button to start the air conditioner Push this button once again to stop it 3 Continue to push the button for 10 seconds to start cooling operation Preparing the f...

Страница 7: ...set up temp display section 4 Operation mode display The selected operation mode is displayed 5 Fan mode display The selected fan mode is displayed LOW MED HIGH 6 Air volume fix display This is not displayed on this model 7 CENTRAL control display Displayed when used with the central remote controller etc 8 STANDBY display It is displayed when the operation cannot be performed though it is not an ...

Страница 8: ...ual attached to each remote controller 1 Operation select button Selects desired operation mode 2 Air volume select button Selects the desired air volume mode 3 Set up temp button Adjusts the required room temperature Match to the desired set temperature by pushing 4 Filter reset button Resets Erases FILTER display 5 CHECK button When an error fault occurs on the air conditioner this button is use...

Страница 9: ...ation mode with MODE button For every push of the button the display changes as right figure 2 Select air volume with the FAN button The display changes as follows LOW MED HIGH AUTO When air volume is AUTO air volume changes according to the room temperature 3 Determine the set up temperature by pushing the TEMP button 4 Push ON OFF button The operation lamp goes on and the operation starts STOP P...

Страница 10: ...lly select either cooling heating or fan only operation depending on the outdoor temperature Start 1 START STOP button Push this button to start the air conditioner 2 Mode select button MODE Select Auto 3 Temperature button Set the desired temperature In case of cooling it starts the operation after approx 1 minute In case of heating the operation mode is selected in accordance with the room tempe...

Страница 11: ... louver manually Always use the LOUVER button If you move the louver manually it may malfuction during operation If the louver malfunctions stop the air conditioner once and restart Adjust the horizontal air flow Preparation Take hold of the lever on the horizontal air flow louver and move them to adjust the air flow direction as you desire You can adjust the air flow at the left center and right ...

Страница 12: ... The lamp will start to indicate after every 1000 hours of operation The FILTER lamp will be out when the TEMPORARY button is pushed The FILTER lamp will also be out when the FILTER button on the remote controller is pushed MAINTENANCE WARNING Before you clean the air conditioner be sure to turn off the circuit breaker or main power switch Cleaning of indoor unit and remote controller CAUTION Use ...

Страница 13: ...left and right handles of the air filter and lift it up slightly then pull it downward to take it out from the filter holder 3 Remove the filters 4 Use a vacuum cleaner to remove the dust from the filters or wash them with water If you wash the air filters dry them in the shade Filter holder Filter holder Air filter 5 Insert the upper portion of the air filter aligning right and left edges on the ...

Страница 14: ...ille is completely closed AIR CONDITIONER OPERATIONS AND PERFORMANCE 3 minute protection function A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation or when the power supply switch is turned on This will protect the machine Heating operation characteristics Preheating operation The air conditioner will...

Страница 15: ...Room temperature Less than 30 C PROBLEMS AND CAUSES CAUTION If any of the following conditions occur turn off the main power supply switch and immediately contact the dealer The indicator lamps flash at short intervals 5 Hz even though you have tried turning off the power supply and turning on again after 2 to 3 minutes Switch operation is erratic The main power fuse often blows out or the circuit...

Страница 16: ...1075000645 ...

Отзывы: