– 44 –
FILE NO. SVM-13050
6-2-3.
Chec
k Code List (Indoor)
: G
o
o
n
,
:
Flash,
:
Go off AL
T (Alter
nate):
Alter
n
ate flashing when there are tw
o flashing LED SIM (Sim
u
ltaneous):
Sim
ultaneous flashing
when there are tw
o flashing LED
(Indoor unit detected)
When this w
a
rn
ing w
a
s detected bef
ore g
roup constr
uction/address chec
k finish at po
w
er supply w
a
s tur
n
ed on, the mode shifts
automatically to A
U
T
O
address setup mode
.
(Remote contr
o
ller detected)
(Central contr
ol de
vices detected)
Chec
k
code indication
TCC-LINK central &
Wired remote contr
oller
E03
E04
E08
E11
E18
F01
F02
F10
F29
L03
L07
L08
L09
L20
L30
P01
P10
P12
P19
P31
Lamp indication
Bloc
k indication
Oper
ation
Timer
Ready
Flash
AL
T
AL
T
AL
T
SIM
SIM
SIM
SIM
SIM
SIM
SIM
AL
T
AL
T
AL
T
AL
T
AL
T
Representative def
e
ctive position
Regular communication error betw
een indoor and
remote controller
Indoor/Outdoor ser
ial error
Duplicated indoor addresses
Communication error between Application control kit and indoor unit
Regular comm
unication error betw
een
indoor master and f
o
llo
w
er units
Indoor unit, Heat e
x
changer (TCJ) error
Indoor unit, Heat e
x
changer (TC) error
Indoor unit, Room temp
. sensor (T
A) error
Indoor unit, other indoor P
.C
. board error
Duplicated setting of indoor group master unit
There is g
roup cab
le in individual indoor unit.
Unset indoor g
roup address
Unset indoor capacity
Duplicated centr
a
l control system address
Outside error input to indoor unit (Inter
loc
k
)
Indoor unit, A
C
f
an error
Indoor unit, o
verflow detection
Indoor unit, DC f
an error
4-wa
y v
a
lv
e system error
Other indoor unit error
Explanation of err
o
r contents
No comm
unication from remote controller and netw
or
k adapter
(Also no comm
unication from centr
al control system)
There is error on ser
ial comm
unication betw
een indoor and outdoor units
Same address as y
o
urs w
a
s detected.
Communication error between Application control kit and indoor unit P.C. board
Regular comm
unication betw
een indoor header and f
o
llo
w
er units is impossib
le
,
Comm
unication betw
e
en twin header (main) and f
o
llo
w
e
r (sub) units is impossib
le
.
Open/shor
t w
a
s detected on heat e
x
changer (TCJ).
Open/shor
t w
a
s detected on heat e
x
changer (TC).
Open/shor
t w
a
s detected on room temp
. sensor (T
A).
EEPR
OM error (Other error ma
y be detected.
If no error
, automatic address is repeated.
There are m
u
ltiple master units in a g
roup
.
When e
ven one g
roup connection indoor unit e
x
ists in individual indoor unit.
Indoor g
roup address is unset.
Capacity of indoor unit is unset.
Duplicated setting of centr
a
l control system address
Abnor
mal stop b
y
outside error (CN80) input
An error of indoor A
C
f
a
n w
a
s detected.
(F
an motor ther
mal rela
y w
o
rk
ed.)
Float s
witch w
o
rk
e
d
.
Indoor DC f
a
n error (Ov
er-current/Loc
k
, etc.) w
a
s detected.
In heating oper
ation, an error w
a
s detected b
y
temp
. do
wn of indoor heat e
x
changer sensor
.
F
ollo
w
e
r unit in g
roup cannot oper
ate b
y
w
a
rn
ing from [E03/L03/L07/L08] of header unit.
Air conditioner operation
A
u
tomatic
Operation
reset
contin
uation
×
× × ×
×
× × ×
×× ×× ×× ×× ××
×
×× ×× ×× ××
× ×
Chec
k
code indication
Wired
remote
contr
oller
E01
E02
E09
Lamp indication
Bloc
k
indication
Oper
ation
Timer
Ready
F
lash
Representative def
e
ctive position
No master remote controller
, Remote controller
comm
unication (Receiv
e
) error
Remote controller comm
unication (Send) error
Duplicated master remote controller
Explanation of err
or contents
Signal cannot be receiv
ed from indoor unit.
Master remote controller w
as not set.
(including 2 remote controllers)
Signal cannot be sent to indoor unit.
In 2-remote controller control, both w
e
re set as master
. (Indoor master unit stops w
a
rn
ing
and f
ollo
w
er unit contin
ues oper
ation.)
Air conditioner operation
A
utomatic
Operation
reset
contin
uation
——
——
×
Chec
k
code indication
TCC-LINK
central
C05
C06
C12
P30
Lamp indication
Bloc
k
indication
Oper
ation
Timer
Ready
F
lash
Is not displa
y
ed.
(Common use
of wired
remote controller
, etc.)
—
By w
a
rn
ing unit
(Abo
ve-mentioned)
Representative def
e
ctive position
Centr
al control system comm
unication (send) error
Centr
al control system comm
unication (receiv
e) error
Gener
al-pur
pose de
vice control interf
a
ce batched w
a
rning
Group f
o
llo
w
e
r unit is def
ectiv
e
.
Explanation of err
or contents
Signal sending oper
ation of centr
a
l control system is impossib
le
.
There are m
u
ltiple same centr
al de
vices
. (AI-NET)
Signal receiving oper
ation of centr
al control system is impossib
le
.
An error on de
vice connected to gener
a
l-pur
pose de
vice control interf
ace of e
x
clusiv
e to
TCC-LINK/AI-NET
Group f
o
llo
w
e
r unit is def
ectiv
e
.
(F
or remote controller
, abo
ve-mentioned [
∗∗∗
] details are displa
y
e
d with unit No
.
Air conditioner operation
A
utomatic
Operation
reset
contin
uation
——
——
——
——
NO
TE:
E
v
en f
o
r the same contents of error such as comm
unication error
, the displa
y of chec
k code ma
y diff
er according to detection de
vice
.
When wired remote controller or centr
al controller detects an error
, it is not necessar
ily related to oper
ation of the air cond
itione
r.
In this list, the chec
k
codes that outdoor unit detects are not descr
ibed.