NOTE

• For environmental conservation, it is strongly recommended that the indoor and outdoor units of the 

air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air 
conditioner.
When the air conditioner is operated for a long time, periodic maintenance (once a year) is 
recommended. 
Furthermore, regularly check the outdoor unit for rust and scratches, and remove them or apply 
rustproof treatment, if necessary.
As a general rule, when an indoor unit is operated for 8 hours or more daily, clean the indoor unit and 
outdoor unit at least once every 3 months. Ask a professional for this cleaning/maintenance work.
Such maintenance can extend the life of the product though it involves the owner’s expense.
Failure to clean the indoor and outdoor units regularly will result in poor performance, freezing, water 
leakage, and even compressor failure.

• This product incorporates a drain pump. 

If it is used in a place full of dust or oil mist, the pump will be clogged and proper drainage is disabled. 
Clean the drain pump periodically. For how to clean the drain pump, contact the dealer.

• Especially when the air conditioner uses 8°C heating operation, take care of operating hours and 

conduct periodic maintenance.

Maintenance List

Part

Unit

Check (visual/auditory)

Maintenance

Heat exchanger

Indoor/outdoor

• Dust/dirt clogging, scratches • Wash the heat exchanger when it is 

clogged.

Fan motor

Indoor/outdoor

• Sound

• Take appropriate measures when 

abnormal sound is generated.

Filter

Indoor

• Dust/dirt, breakage

• Wash the filter with water when it is 

contaminated.

• Replace it when it is damaged.

Fan

Indoor

• Vibration, balance
• Dust/dirt, appearance

• Replace the fan when vibration or 

balance is terrible.

• Brush or wash the fan when it is 

contaminated.

Air inlet/outlet grilles

Indoor/outdoor

• Dust/dirt, scratches

• Fix or replace them when they are 

deformed or damaged.

Drain pan

Indoor

• Dust/dirt clogging, drain 

contamination

• Clean the drain pan and check the 

downward slope for smooth 

drainage.

Ornamental panel, 

louvers

Indoor

• Dust/dirt, scratches

• Wash them when they are 

contaminated or apply repair 

coating.

Exterior

Outdoor

• Rust, peeling of insulator
• Peeling/lift of coat

• Apply repair coating.

20-EN

+00EH99930901-2_10L_4-way_OM.book  Page 20  Friday, April 17, 2009  2:39 PM

Содержание RAV-SM1104UT-E

Страница 1: ...houdelijk gebruik Μη προσβάσιμο από το γενικό κοινό Недоступен для посторонних Genel erişime açık değildir Manuel du proprietaire Climatiseur Type split 25 Français Betriebsanleitung Klimagerät Split typ 49 Deutsch Manuale del proprietario Condizionatore d aria Tipo split 73 Italiano Manual del propietario Aire acondicionado Tipo split 97 Español Manual do utilizador Ar condicionado Tipo split 121...

Страница 2: ...BA Air Conditioner Please read this owner s manual carefully before using your Air Conditioner Be sure to obtain the Owner s manual and Installation manual from constructor or dealer Request to constructor or dealer Please clearly explain the contents of the Owner s manual and hand over it ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type which adopts a new refrigerant HFC R410A inste...

Страница 3: ...auses the internal fan to run at a high speed in some modes even while the air conditioner is not working which may cause injury Do not attempt it yourself Avoid cooling the room too strong or exposing the human body to cool breeze for a long time as it is bad for the health When you notice something abnormal with the air conditioner smells like something scorching poor cooling etc immediately tur...

Страница 4: ...r for special purpose such as preserving food precision instruments art objects breeding animals car vessel etc When the air conditioner is operated with a combustion appliance in the same place be careful of ventilation to let fresh air enter the room Poor ventilation causes oxygen shortage Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditione...

Страница 5: ...n of the air to be discharged according to cool heat mode Discharge louver of discharge port The air in the room is sucked in from this port Suction air port Projection of air filter SET TIME TIMER SET TEST FILTER RESET CL FAN SAVE SWING FIX VENT MODE UNIT LOUVER Remote controller Separate sold part Air inlet Side and rear Panel There is an earth screw valves and electric parts inside Air outlet P...

Страница 6: ...displayed When a trouble occurs the check code is displayed 5 Timer SET IN setup display When pushing the Timer SET IN button the display of the timer is selected in order of OFF OFF repeat OFF timer ON No display 6 Filter display If FILTER is displayed clean the air filter 7 TEST run display Displayed during a test run 8 Louver position display Displays louver position 9 SWING display Displayed d...

Страница 7: ...oor unit 19 Unit Number display Unit number of the indoor unit selected with the unit select button or abnormal indicate the indoor outdoor unit 20 Central control display Displayed when the air conditioner is used under the central control in combination with a central control remote controller In case the remote controller is disabled by the central control system flashes The button operation is...

Страница 8: ...e louver direction 8 Operation lamp Lamp is lit during the operation Lamp is off when stopped Although it flashes when operating the protection device or abnormal time 9 button When the button is pushed the operation starts and it stops by pushing the button again When the operation has stopped the operation lamp and all the displays disappear 10 button Operation select button Selects desired oper...

Страница 9: ...lamp goes on and the operation starts 2 Select an operation mode with the MODE button One push of the button and the display changes in the order shown as follows 3 Select air volume with button One push of the button and the display changes in the order shown as follows When air volume is AUTO air volume differs according to the room temperature In heating operation if the room temperature is not...

Страница 10: ...o about 8 C in the heating mode The 8 C heating operation requires settings with the wired remote controller Ask the installer or dealer for the settings according to the installation manual of the indoor unit Start Stop CAUTION Do not keep the louver position horizontally in the 8 C heating operation since the heating performance degrades NOTE The discharged air temperature is lower than that in ...

Страница 11: ...ours 1 In the case of 34 hours 2 3 Push SET button display disappears and timer time display goes on and or display flashes When ON timer is activated timer time ON timer are displayed and other displays disappear 4 Cancel of timer operation Push button TIMER display disappears NOTE When the operation stops after the timer reached the preset time the Repeat OFF timer resumes the operation by pushi...

Страница 12: ...f the louvers stay pointed straight out horizontally when heating the room temperature may be unevenly distributed When the air conditioner is not working the louvers are directed horizontally automatically The louvers are directed horizontally when heating begins during defrost operation or during the minimum operation after reaching the set temperature When you make a swing or air direction sett...

Страница 13: ...on Display when swinging is stopped In this case push again two seconds later In COOL DRY operation the louver does not stop as it directs downward If stopping the louver as it directs downward during swing operation it stops after moving to the third position from the highest position Display when stopping the swing Unit select button When multiple indoor units are controlled with one remote cont...

Страница 14: ...just change by pushing right side of the button Each time you push the button the display on the left of the remote controller changes as follows When no louver number is displayed all four louvers are selected 3 Determine wind direction of the selected louver by pushing Each time you push the button the display changes as follows During COOL DRY mode 4 and 5 are not displayed 3 1 2 Unit select bu...

Страница 15: ...er saving mode 8 SELF CLEANING MODE This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling dry AUTO cooling mode to keep the indoor unit clean The self cleaning time varies with the cooling dry AUTO cooling operation time as follows is displayed on the remote controller during self cleaning operation To stop self cleaning forcibly push button ...

Страница 16: ... may cause a failure of the louvers Standard swing The four louvers swing in the same direction About Dual swing Dual swing means that louvers 01 and 03 are directed and swing in one direction and then louvers 02 and 04 are directed and swing in the opposite direction When louver 01 is directed downward louver 02 is directed horizontally About Cycle swing The four louvers swing independently at re...

Страница 17: ...s selected dew drop may occur during cooling mode 5 Determine the setting by pushing button When the setting has been determined lights up To continue louver lock settings for other indoor units repeat from step 2 To continue louver lock settings for other louvers on the same indoor unit repeat from step 3 6 Push button to complete the setting A louver number is displayed as F1 F2 on the remote co...

Страница 18: ...push the button unit numbers change as follows The fan of the selected unit runs and the louvers start swinging 3 Adjust the power save setting by pushing TIME buttons Each push of the button changes the power level by 1 within the range from 100 to 50 The factory setting is 75 When the air conditioner is connected to the following outdoor unit the display section of the power saving mode of a rem...

Страница 19: ...ivated the current operation stops and the operation lamp and on the remote controller flash When the protective device is activated When the protective device has been activated and stopped operation turn off the leakage breaker immediately and ask the installer to find the cause If the air conditioner is operated without fixing the problem the air conditioner may malfunction Check whether the ai...

Страница 20: ...very dirty Never use a damp cloth on the remote controller Do not use a chemically treated duster for wiping or leave such materials on the unit for long It may damage or fade the surface of the unit Do not use benzine thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform Periodic check Long period use of the air conditioner may cause dete...

Страница 21: ...pump will be clogged and proper drainage is disabled Clean the drain pump periodically For how to clean the drain pump contact the dealer Especially when the air conditioner uses 8 C heating operation take care of operating hours and conduct periodic maintenance Maintenance List Part Unit Check visual auditory Maintenance Heat exchanger Indoor outdoor Dust dirt clogging scratches Wash the heat exc...

Страница 22: ...ration During the defrosting operation the defrosted water will be drained from the bottom plate of the outdoor unit Heating capacity In the heating operation the heat is absorbed from the outside and brought into the room This way of heating is called heat pump system When the outside temperature is too low it is recommended to use another heating apparatus in combination with the air conditioner...

Страница 23: ...nstall the air conditioner in a humid or oily place or in a place where steam soot or corrosive gas is generated Do not install the air conditioner in a salty place such as seaside area Do not install the air conditioner in a place where a great deal of machine oil is used Do not install the air conditioner in a place where it is usually exposed to strong wind such as in seaside area Do not instal...

Страница 24: ... and maintenance shall be carried out by a qualified person Failure to clean the indoor outdoor units regularly will result in poor performance freezing water leaking and even compressor failure This product incorporates a drain pump If it is used in a place full of dust or oil mist the pump will be clogged and proper drainage is disabled Clean the drain pump periodically For how to clean the drai...

Страница 25: ...ter drains from outdoor unit The outdoor unit is sometimes frosted in heating operation In that case the unit automatically performs defrosting for 2 to 10 minutes for increasing the heating efficiency In defrosting operation both the indoor and outdoor units stop air flow Hiss sound is heard when flow of the refrigerant is changed for defrosting Resultant water of automatic defrosting in heating ...

Страница 26: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 23 17 Takanawa 3 Chome Minatoku Tokyo 108 8580 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Отзывы: