Installation Manual
–
44
–
44-EN
13
MAINTENANCE
¡
Daily maintenance
Cleaning of air
¿
lter
1
Push the
button to stop the operation,
then turn off the circuit breaker.
After the cooling or dry operation, the
ventilation fan keeps running for
self-cleaning. Push the
button twice
to stop the operation.
Take out the air
¿
lter
1
Open the air intake grille until it stops, and
slightly raise the hook on the lower centre
of the air
¿
lter.
The air intake grille should not be opened
further; otherwise, the arms may come off and
the air intake grille may fall down.
Air
¿
lter
Cleaning with water or vacuum cleaner
If dirt is heavy, clean the air
¿
lter by tepid water
with neutral detergent or water.
After cleaning with water, dry the air
¿
lter
suf
¿
ciently in a shade place.
Mount the air
¿
lter
2
Turn on the circuit breaker, then push the
button on the remote controller to
start the operation.
1,2
CAUTION
•
Do not start the air conditioner while leaving
air
fi
lter removed.