4
Timer
operation
5
Adjustment of wind direction
For best cooling and heating performance, adjust the
louvers (adjustment plates of up / down wind direction)
appropriately. Cold air descends and warm air rises, so
to heat a room tilt the louvers downward, and to cool a
room tilt them horizontally.
CAUTION
Direct the louvers horizontally for cooling.
If the louvers stay pointed downward during cooling,
condensation may form on the discharge port and /
then drops from the louvers.
• When operation is stopped, the horizontal louver
(plate for adjusting the vertical air
fl
ow) automatically
closes.
• In heating preparation mode, the horizontal louver
(plate for adjusting the vertical air
fl
ow) points
upward. The louver starts swinging when the heating
preparation mode has
fi
nished, but the swing
indicator appears on the remote controller even in
heating preparation mode.
As characteristics of air, cold air
accumulates lower area and warm
air accumulates upper area.
To set the louver direction and auto swing
1
Push the Menu button several times and select
the wind direction mode to blink the wind
direction.
2
Push the setting button several times to display
the louver direction as shown in the
fi
gure below.
• If you do not push any button for 30s, the wind
direction mode
fi
nishes.
For heating
The louver can be adjusted to six steps.
Point the louver downward. If not pointing downward,
hot air may not reach the
fl
oor.
Initial
(1)
(2)
(3)
(4)
(5)
(6)
(Swing)
Operation mode
Available directions
HEAT, FAN
(1)
↔
(2)
↔
(3)
↔
(4)
↔
(5)
↔
(6)
For cooling
The louver can be adjusted to four steps.
Point the louver horizontally. If pointing downward, dew
may form on the surface of the air discharge port and
may drop down.
If a louver lock setup is carried out in the position of
(1), fan speed will be restricted for prevention of ceiling
contamination.
Initial
(1)
(2)
(3)
(4)
(Swing)
Operation mode
Available directions
COOL, DRY
(1)
↔
(2)
↔
(3)
↔
(4)
4.1 Timer off Operation
Timer off: When reaching the setting time, the indoor unit stops running.
1
Timer off button
Press the timer off button in process of air conditioner operation.
• The and
light, while
and timing indication icon
fl
icker.
2
Select the timer off time
Press the set button to set the time.
• Increase in accordance with the law of 0.5 hour(30 minutes), 1 hour, 2 hours ..., it can be up to 24 hours.
• If you do not operate the button within 30 seconds, the timer off setting will be canceled.
3
Press the timer off button
The
disappears and the timer off indication icon changes from
fl
ickering to normally on, then the timer off
function starts.
When running the shutdown timer, the timing indication is displayed in the form of countdown.
■
Cancel timing
1
Press the timer off button.
The timing indication icon disappears.
NOTE
• When the shutdown timer is running, it will continue to run even if the air conditioner is turned on or off via the
on/off button.
– 10 –
19-EN
20-EN