Toshiba RAS-B10U2FVG-E1 Скачать руководство пользователя страница 6

The unit does not operate.

Cooling or Heating is abnormally low

• 

The power main switch is 
turned off.

• 

The circuit breaker is activated 
to cut off the power supply.

• 

Stoppage of electric current.

• 

ON timer is set.

• 

The 

fi

lters are blocked with dust.

• 

The temperature has been set 
improperly.

• 

The windows or doors are opened.

• 

The air inlet or outlet of the outdoor 
unit is blocked.

• 

The fan speed is too low.

• 

The operation mode is DRY.

• 

POWER SELECTION function is 
set 75% or 50% (

This function is 

depend on remote controller

).

Note

:   When there is an abnormality in the product, abnormal code 

(2 digits) will be displayed on the unit display panel. Please contact 
the dealership.

In case of multiple connection
• 

Check whether the operation mode is different from what has been selected 
for the units in the other rooms (The following combinations of operations 
cannot be performed: COOL and HEAT, DRY and HEAT).

• 

Select the same operation mode as for the other rooms.

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed near.

Remote Control B Setup.

1.  Push and hold 

CHECK

 button on the Remote Control by the tip of the 

pencil. “00” will be shown on the display. (Picture 

1

)

2.  Press 

 during pushing 

CHECK

. “B” will show on the display and “00” 

will disappear and the air conditioner will turn OFF. The Remote Control 
B is memorized. (Picture 

2

)

Note: 

1. Repeat above step to reset Remote Control to be A.

 

2. Remote Control A has not “A” display.

 

3. Default setting of Remote Control from factory is A.

1

2

B

Unit B setup.

Press and hold MODE button for more than 20 seconds.
When A setup changed to B setup : 5 beeps will sound and operation lamp 
blinks for 5 seconds.
When B setup changed to A setup : 5 beep will sound.

Wash the air inlet grille with water using the soft sponge or towel.

• 

Dry it well in a shadow area after washing. 

• 

Scour heavy dirt with neutral detergent for kitchen, and rinse it with the 
water (Do not use the wire wool).

• 

Do not press the front panel strongly. It may be cracked.

Power-Selection (

)

This function is used when the circuit breaker is shared with other electrical 
appliances. It limits the maximum current and power consumption to 100%, 
75%, or 50% and can be implemented by POWER-SELECTION. The lower 
percentage, the higher saving and also longer compressor lifetime.

Note

:  

• 

When the level is selected, POWER-SEL level 

fl

ashes on remote LCD 

display for 3 seconds.
In case of 75% and 50% level, number “75” or “50” also 

fl

ashes for 2 

seconds.

• 

Due to the reason that POWER-SELECTION function limits the 
maximum current, inadequate cooling or heating capacity may occur.

Silent Operation (

)

Keep outdoor unit operating silently to ensure either yourself or neighborhood 
will have a tight sleep in nighttime. By this feature, the heating capacity will 
be optimized to deliver such silent experience. The silent operation can be 
selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2

Silent 1:

Though operating silently, the Heating (or Cooling) capacity is still prioritized to 
ensure having suf

fi

cient comfort inside the room.

This setting is a perfect balance between the Heating (or Cooling) capacity 
and the Sound level of outdoor unit.

Silent 2:

Compromising the Heating (or Cooling) capacity to the Sound level in any 
circumstance where the outdoor unit’s sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor unit 
by 4 dB(A).

Note

:  

• 

While activating of Silent operation, inadequate heating (or cooling) 
capacity may occur.

Power-Selection and Silent Operation (Outdoor Unit)

1.  Press and hold AIR OUTLET SELECT button then press MODE button 

for 3 times (All lamp of the unit display panel will be switched on). (At that 
time, please press and hold the AIR OUTLET SELECT button)

2.  Press and hold AIR OUTLET SELECT button on Unit display panel, 

then press TEMPERATION button (Up), (Down) for select the desired 
brightness.

3.  Brightness will be settled when AIR OUTLET SELECT button is released. 

Although the temperature indicator is switched off, if press the temperature 
button (up) and (down), the set temperature will be indicated, and then can 
adjust the temperature. 
10 seconds after stopped pressing the button, the temperature indication 
will be switched off.

4 stages of brightness can be changed.

Temperature indicator

Other lamp

1

Usual

Usual

2

Darkness

Darkness

3

Turn off

Darkness

4

Turn off

Turn off

On cooling operation, whichever air outlet is set, only Upper is used when the 
room temperature approaches the set temperature. 
In case to keep up/down blowing, operate as below; 
Press and hold AIR OUTLET SELECT button for more than 10 seconds (less 
than 20 seconds) (4 beeps will sound then “1” indication at TEMPERATURE 
indicator will light up for 5 seconds). 
For return to the former status, press and hold AIR OUTLET SELECT button 
for more than 10 seconds once again (In this time, 4 beeps will sound then “0” 
indication at TEMPERATURE indicator will blinks for 5 seconds).

TROUBLESHOOTING (CHECK POINT)

18

REMOTE CONTROL A-B SELECTION

19

AIR INLET GRILLE MAINTENANCE

22

POWER-SELECTION AND SILENT 

OPERATION (OUTDOOR UNIT)

23

ADJUSTING BRIGHTNESS OF UNIT 

DISPLAY PANEL

20

CHANGE AIR OUTLET GRILLE ON 

STABLE TIME (COOLING ONLY)

21

[100%]

[75%]

[50%]

SILENT#2

SILENT#1

Содержание RAS-B10U2FVG-E1

Страница 1: ...1112150198 AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS B10 13 18U2FVG E1 OWNER S MANUAL ...

Страница 2: ...losion or injury do not operate the unit when harmful gases e g flammable or corrosive are detected near the unit WARNING Do not expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner and disconnect the power supply or turn off the breaker This appliance c...

Страница 3: ...ion Else it may explode and cause injury or death When the indoor unit is connected with multi split R32 outdoor unit 3M26 4M27 and 5M34 Please see IMS outdoor unit installation manual and consult your dealer about the minimum floor area CAUTION Do not wash the unit with water It may cause an electric shock Do not use this air conditioner for other purposes such as preserving food breeding animal ...

Страница 4: ...ess MODE button for 3 seconds It is possible to operate even when stopping To cancel CHILD LOCK function press MODE button for 3 seconds once again When CHILD LOCK function is activated 3 beeps will sound When press MODE button to cancel the function a beep will sound and then 3 seconds later 3 beep sound may occur The indicator button will be invalid while the child lock function is activated Whe...

Страница 5: ... your preferred operation for future use The setting will be memorized by the unit for future operation except airflow direction 1 Select your preferred operation 2 Press and hold until stop blinking and the P mark displays 3 Press Operate the preset operation 1 Three minute protection feature To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON 2 Prehea...

Страница 6: ...nadequate cooling or heating capacity may occur Silent Operation Keep outdoor unit operating silently to ensure either yourself or neighborhood will have a tight sleep in nighttime By this feature the heating capacity will be optimized to deliver such silent experience The silent operation can be selected from one of two purposes Silent 1 and Silent 2 There are three setting parameters Standard le...

Страница 7: ...1112150198 ...

Отзывы: