12

EN

• A place which provides enough space around the outdoor unit as shown in the diagram.
• A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration.
• A place where the operation noise and discharged air do not disturb neighbors.
• A place which is not exposed to a strong wind.
• A place free of combustible gases.
• A place which does not block a passageway.
• When the outdoor unit is to be installed in an elevated position, be sure to secure its feet.
• This air conditioner accepts a connection piping length of up to 25 m.

• There is no need to add refrigerant as long as the length of the connection piping is 15 m or less.
• You will need to add 20 g of refrigerant per meter of added connection piping for installations requiring connection piping to be 

between 16 m to 25 m.

• An allowable height level is up to 10 m.
• A place where the drain water does not cause any problems.

Precautions for Adding Refrigerant

• Use a scale having a precision with at least 10 g per index line when adding the refrigerant. Do not use a bathroom scale or similar 

instrument.

• Use liquid refrigerant when refilling the refrigerant. Since the refrigerant is in liquid form, it can fill quickly. Therefore, perform the 

filling operation carefully and insert the refrigerant gradually.

• Holes are provided on the base plate of the outdoor unit to ensure that the 

defrost water produced during heating operations is drained off efficiently. If a 
centralized drain is required when installing the unit on a balcony or wall, follow 
the steps below to drain off the water.

1.

Proceed with water-proofing by installing the water-proof rubber caps 

j

 in the 

2 elongated holes on the base plate of the outdoor unit.
[How to install the water-proof rubber caps]
1) Place four fingers into each cap, and insert the caps into the water drain 

holes by pushing them into place from the underside of the base plate.

2) Press down on the outer circumferences of the caps to ensure that they 

have been inserted tightly.
(Water leaks may result if the caps have not been inserted properly, if their 
outer circumferences lift up or the caps catch on or wedge against 
something.)

2.

Install the drain nipple 

i

 and a commercially available drain hose (with 16 mm 

inside diameter), and drain off the water.
(For the position where the drain nipple 

i

 is installed, refer to the installation 

diagram of the indoor and outdoor units.)

• Check that the outdoor unit is horizontal, and route the drain hose at a 

downward sloped angle while ensuring that it is connected tautly.

5 INSTALLATION OF OUTDOOR UNIT

Installation Location

CAUTION

1.

Install the outdoor unit without anything blocking the discharging air.

2.

When the outdoor unit is installed in a place always exposed to strong winds like on the coast or on a high story of a 
building, secure the normal fan operation using a duct or a wind shield.

3.

Especially in windy areas, install the unit to prevent the admission of wind.

4.

Installation in the following places may result in trouble. Do not install the unit in such places.
• A place full of machine oil.
• A saline-place such as the coast.
• A place full of sulfide gas.
• A place where high-frequency waves are likely to be generated, such 

as from audio equipment, welders, and medical equipment.

Draining the water

Strong 
wind

j

 Water-proof rubber 

caps (supplied with the 
outdoor unit)

i

 Drain nipple

Base plate

Commercially available 
drain hose

Do not use ordinary garden hose, which can flatten and 
prevent water from draining.

Base plate

i

 Drain nipple

Содержание RAS-B10GKVP-E

Страница 1: ...ngerät Unità interna Unità esterna Unidad interior Unidad exterior Εσωτερική µονάδα Εξωτερική µονάδα Unidade interior Unidade exterior Innedel Utedel Внутренний блок Наружный блок RAS B10GKVP E RAS B13GKVP E RAS B16GKVP E RAS M10GKCVP E RAS M13GKCVP E RAS M16GKCVP E RAS 10GAVP E RAS 13GAVP E RAS 16GAVP E RAS M14GAV E RAS M18GAV E RAS M14GACV E RAS M18GACV E Please read this installation manual car...

Страница 2: ...EXTERIOR 3 3 PARTES OPCIONALES ACCESORIOS Y HERRAMIENTAS 4 4 INSTALACIÓN DE LA UNIDAD INTERIOR 6 5 INSTALACIÓN DE LA UNIDAD EXTERIOR 12 6 OPERACIÓN DE PRUEBA 16 1 ΠΡΟΦΥΛΑΞΕΙΣ ΑΣΦΑΛΕΙΑΣ 1 2 ΕΙΚΟΝΕΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΕΣΩΤΕΡΙΚΗΣ ΚΑΙ ΕΞΩΤΕΡΙΚΗΣ ΜΟΝΑ ΑΣ 3 3 ΠΡΟΑΙΡΕΤΙΚΑ ΑΝΤΑΛΛΑΚΤΙΚΑ ΕΞΑΡΤΗΜΑΤΑ ΚΑΙ ΕΡΓΑΛΕΙΑ 4 4 ΕΓΚΑΤΑΣΤΑΣΗ ΕΣΩΤΕΡΙΚΗΣ ΜΟΝΑ ΑΣ 6 5 ΕΓΚΑΤΑΣΤΑΣΗ ΕΞΩΤΕΡΙΚΗΣ ΜΟΝΑ ΑΣ 12 6 ΟΚΙΜΑΣΤΙΚΗ ΛΕΙΤΟΥΡΓΙΑ 16 1 P...

Страница 3: ...ANY ELECTRICAL WORK MAKE SURE ALL POWER SWITCHES ARE OFF FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK CORRECTLY CONNECT THE CONNECTING CABLE IF THE CONNECTING CABLE IS INCORRECTLY CONNECTED ELECTRIC PARTS MAY BE DAMAGED CHECK THAT THE EARTH WIRE IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPO...

Страница 4: ...nstallation may result in an electrical short Do not store in a wet basement or expose to rain or water After unpacking the unit examine it carefully for any damage Do not install in a place that can increase the vibration of the unit Do not install in a place that can amplify the noise level of the unit or where noise or discharged air might disturb neighbors To avoid personal injury be careful w...

Страница 5: ...ol holder mounting screw For the rear left and left piping Wall Do not allow the drain hose to become slack Cut the piping hole slightly sloped Insulate the refrigerant pipes separately not together With the remote control cover removed correctly load the supplied batteries while observing their polarity Cover b Wireless remote control c Batteries b Wireless remote control Hook a Installation plat...

Страница 6: ... Part No Part name Q ty Part No Part name Q ty Part No Part name Q ty a Installation plate x 1 d Remote control holder x 1 g Mounting screw φ4 x 25L x 6 b Wireless remote control x 1 e Zeolite plus filter x 1 h Remote control holder mounting screw φ3 1 x 16L x 2 c Battery x 2 f Plasma pure filter x 1 i Drain nipple x 1 RAS 10GAVP E 13GAVP E 16GAVP E j Water proof rubber cap x 2 RAS 10GAVP E 13GAVP...

Страница 7: ...o prevent any other refrigerant from being charged the port diameters have been changed Charge hose In order to increase pressure resisting strength hose materials and port sizes have been changed to 1 2 UNF 20 threads per inch When purchasing a charge hose be sure to confirm the port size Electronic balance for refrigerant charging As working pressure is high and gasification speed is fast it is ...

Страница 8: ...ment This is necessary to prevent image disturbance or noise interference The location of the remote control should be determined as shown below Drilling a hole When installing the refrigerant pipes from the rear 1 After determining the pipe hole position on the installation plate drill the pipe hole φ65 mm at a slight downward slant to the outdoor side NOTE When drilling into a wall that contains...

Страница 9: ... NOTE Install the installation plate using between 4 to 6 mounting screws being sure to secure all four corners 1 The supply voltage must be the same as the rated voltage of the air conditioner 2 Prepare a power source for the exclusive use of the air conditioner NOTE Wire type H07RN F or 245IEC66 1 0 mm2 CAUTION When installing the installation plate with mounting screws do not use anchor bolt ho...

Страница 10: ...inal cover rear plate bushing and air inlet grille on the indoor unit CAUTION This appliance can be connected to a main circuit breaker in either of the following two ways 1 Connection to fixed wiring A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporate in the fixed wiring An approved circuit breaker or switch must used 2 Connect...

Страница 11: ...out How to remove the drain hose The drain hose is secured in place by a screw Remove the screw securing the drain hose then pull out the drain hose How to attach the drain cap 1 Insert hexagonal wrench 4 mm 2 Firmly insert drain cap How to attach the drain hose Insert the drain hose firmly until the connector contacts the insulation then secure it in place using the original screw Piping and Drai...

Страница 12: ...ound them Outer diameter Bending radius 6 35 mm 30 mm 9 52 mm 40 mm 12 7 mm 50 mm CAUTION Bind the auxiliary pipes two and connecting cable with facing tape tightly In case of leftward piping and rear leftward piping bind the auxiliary pipes two only with facing tape Carefully arrange the pipes so that none of the pipes stick out of the rear plate of the indoor unit Carefully connect the auxiliary...

Страница 13: ...on the outdoor side 2 Put water in the drain pan and make sure that the water is being drained outside 3 When connecting extension drain hose insulate the connection part of extension drain hose with shield pipe This air conditioner has been designed to drain water collected from condensation which forms on the back of the indoor unit to the drain pan Therefore do not locate the power cord and oth...

Страница 14: ... the 2 elongated holes on the base plate of the outdoor unit How to install the water proof rubber caps 1 Place four fingers into each cap and insert the caps into the water drain holes by pushing them into place from the underside of the base plate 2 Press down on the outer circumferences of the caps to ensure that they have been inserted tightly Water leaks may result if the caps have not been i...

Страница 15: ...ghten the flare pipes which connect the outdoor unit and the indoor unit with the specified tightening torque using a torque wrench If any flare pipe is incorrectly connected it may cause not only a gas leakage but also trouble in the refrigeration cycle Refrigerant Piping Connection Outer diameter of copper pipe R410A tool used Conventional tool used 6 35 0 to 0 5 1 0 to 1 5 9 52 0 to 0 5 1 0 to ...

Страница 16: ...essure gauge reading is 101 kPa 76 cmHg 5 Close the low pressure valve handle of gauge manifold 6 Open fully the valve stem of the packed valves both sides of Gas and Liquid 7 Remove the charging hose from the service port 8 Securely tighten the caps on the packed valves Evacuating AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump Do not use the refriger...

Страница 17: ...ximum running current 12A Installation fuse rating 25A D type Power cord H07RN F or 245IEC66 1 5 mm2 Connecting cable Wire type H07RN F or 245IEC66 1 0 mm2 CAUTION Incorrect wiring connection may cause electrical parts to burn out Be sure to comply with local regulations codes when running the wire from outdoor unit to indoor unit Size of wire and wiring method etc Every wire must be securely conn...

Страница 18: ...t panel and then set the selector switch to B After making the switch setting remount the front panel 2 Setting the remote control a Slide open the remote control cover and remove the batteries b Cut the jumper wire inside the battery compartment using nippers The jumper wire should not remain in contact after being cut Also be careful not to let plastic scraps jumper wire cuttings or other debris...

Страница 19: ...prodotto è conforme alla direttiva 2002 95 CE e per disfarsene non deve essere gettato con la spaz zatura della casa Este producto cumple con la Directiva 2002 95 EC y no se puede desechar como la basura municipal Το προϊόν αυτό συµµορφώνεται µε την Οδηγία 2002 95 ΕΕ και δεν µπορεί να απορριφτεί ως µη ταξινοµηµένο δηµοτικό απόβλητο Este produto respeita a Directiva 2002 95 EC e não pode ser deitad...

Отзывы: