![Toshiba RAS-4M27UAV-E Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/toshiba/ras-4m27uav-e/ras-4m27uav-e_service-manual_1135054075.webp)
– 75 –
9-3. Auto Restart Function
This indoor unit is equipped with an automatic restarting function which allows the unit to restart operating with the
set operating conditions in the event of a power supply being accidentally shut down.
The operation will resume without warning 3 minutes after power is restored.
This function is not set to work when shipped from the factory. Therefore it is necessary to set it to work.
9-3-1. Setting the Auto Restart Function
To set the auto restart function, proceed as follows:
The power supply to the unit must be on ; the function will not set if the power is off.
Push the [RESET] button located in the center of the front panel continuously for 3 seconds.
The unit receives the signal and beeps 3 times.
The unit then restarts operating automatically in the event of power supply being accidentally shut down.
• When the unit is standby (Not operating)
• When the unit is in operation
NOTE
• After restarting the air conditioner by the AUTO RESTART OPERATION, the louver swing (AUTO) operation
doesn’t resume.
• While the PURE indicator (Orange) is on, the RESET button has the function of air purifier reset button.
Operation
Motions
Push [RESET] button for more than
3 seconds. (Less than 10 seconds)
The unit is on standby.
(Push [RESET] button for more than 3 seconds.)
The unit starts to operate.
The green indicator is on.
After approx. 3 seconds,
The unit beeps 3 times and
continues to operate.
The green indicator flashes for
5 seconds.
If the unit is not required to operate at this time, push [RESET] button
once more or use the remote controller to turn it off.
Operation
Motions
Push [RESET] button for more than
3 seconds. (Less than 10 seconds)
The unit is in operation.
The green indicator is on.
(Push [RESET] button for more than 3 seconds.)
The unit stops operating.
The green indicator is turned off.
After approx. 3 seconds,
The unit beeps 3 times.
The green indicator flashes for
5 seconds.
If the unit is required to operate at this time, push [RESET] button once
more or use the remote controller to turn it on.
K
K
K
K
+00A10-023_01EN.book Page 75 Wednesday, April 6, 2011 2:43 PM