9-2. Operation Description
1. Basic operation ........................................................................................................... 2
7
1. Operation control ................................................................................................... 2
7
2. Cooling/Heating operation ..................................................................................... 2
8
3. AUTO operation ..................................................................................................... 2
8
4. DRY operation
........................................................................................................ 2
8
2. Indoor fan motor control .............................................................................................
29
3. Outdoor fan motor control........................................................................................... 3
1
4. Capacity control .......................................................................................................... 3
2
5. Current release control ............................................................................................... 3
2
6. Release protective control by temperature of indoor heat exchanger........................ 3
3
7. Defrost control (Only in heating operation) ................................................................ 3
4
8. Louver control ............................................................................................................. 3
5
1) Louver position
....................................................................................................... 3
5
2) Wind direction adjustment ..................................................................................... 3
5
3) Swing ..................................................................................................................... 3
5
9. ECO operation ............................................................................................................
36
10. Temporary operation...................................................................................................
37
1
1
. Discharge temperature control ...................................................................................
37
1
2
. High pressure control .................................................................................................
38
1
3
.
Self-Cleaning function ................................................................................................
39
1
4
.
Remote-A or B selection ............................................................................................ 4
1
2
2
.
1
5
.
QUIET mode ............................................................................................................. 4
2
1
7
.
Display lamp brightness adjustment
.
..
....................................................................... 4
2
18.
Short Timer ................................................................................................................ 4
4
21
.
2
4
.
POWER Selection
Mode
.
..............
............
....
.....................................................
4
4
Cord Heater Control
............................................................................................
47
2
8
.
Outdoor Quiet Control
.........................................................................................
4
6
Pulse Modulating valve (P.M.V.) control ......................................................................
38
2
3
.
Silent Operation
.
.........................
............
....
.....................................................
4
5
2
5
.
Operation mode selectable
.
........
.....................................................................
4
6
2
6
.
Fireplace Operation
..........................................................
............
....................
47
2
7
.
8 degree heating / Frost protective Operation
..................................................
47
9-3. Auto Restart Function
..
9-3-1. How to Set the A uto Restart Function .......................................................................
48
9-3-2. How to Cancel the Au to Restar t Function .................................................................
49
9-3-3. Power Failure During Timer Operation ....................................................................
49
9-4. Remote
Control
9-4-1.
Remote control and its functions
...........................................
.................
..................... 5
0
9-4-2. Operation of remote control ....................................................................................... 5
0
9-4-3. Name and Functions of Indications on Remote Contr oller .........................................
58
Hi-POWER Mode
..................................
...............
..................................................... 4
1
1
6
.
Filter Indicator
......................................................................
....................
..........
.
....... 4
2
19.
Defrost control (only in heating operation)
...................................
.............
..........
.
....... 4
3
20
.
FILE NO. SVM-17057