When the installation plate is directly
mounted on the wall
1. Securely fit the installation plate onto the wall by
screw
ing it in the
upper and lower
parts to
h
ook up the indoor unit.
2. To mount the installation plate on a concrete wall
with anchor bolts, use the anchor bolt holes as
illustrated in the below figure.
3. Install the installation plate horizontally
in the wall
.
CAUTION
When installing the installation plate with mounting
screw, do not use the anchor bolt hole
s
.
Otherwise
,
the unit may fall down and result in
personal injury and property damage.
Fig. 10-3-4
Fig. 10-3-5
CAUTION
Failure to securely install the unit may result in
personal injury and property damage if the
unit falls.
• In case of block, brick, concrete or similar type
walls,
make
5 mm dia. holes in the wall.
• Insert clip anchors for
appropriate mounting
Anchor bolt
Projection
15 mm or less
5 mm dia. hole
Clip anchor
(local parts)
7 Mounting screw
Ø4 × 25
l
10-3-
3
. Wiring Connection
How to connect the connecting cable
Wiring
of
the connecting cable can be carried
out without removing the front panel.
1. Remove the air inlet grille. Open the air inlet
grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (or as according to
local r
ule
) into the pipe hole on the
wall.
4.
Take out
the connecting cable through the cable
slot
on the rear panel so that it protrudes about
15 cm
from
the front.
5. Insert the connecting cable fully into the terminal
block and secure it tightly with screws.
6. T
ighten firmly but not over :
1.2 N•m (0.12 kgf•m)
7. Secure the connecting cable with the cord clamp.
8.
Fix
the terminal cover, rear plate bushing and
air inlet grille on the indoor unit.
FILE NO. SVM-13004
screws 7 .
NOTE :
•
Secure four corners and lower parts
the installation plate
with
4 to 6
mounting screws to install it.
CAUTION
•
Be sure to refer to the wiring system diagram
labeled inside the front panel.
•
Check local electrical cords and also any specific
wiring instructions or limitations.
CAUTION
1
2
3
Cord clamp
Terminal block
Terminal cover
Screw
Earth line
Screw
Connecting cable
Earth line
110mm
20mm
80mm
10mm
Connecting
cable
Stripping length of the connecting cable
About 15 cm
Fig. 10-3-6
NOTE :
•
Use stranded wire only.
•
Wire type : More than 1.5 mm (H07RN-F or 60245
IEC66) or 1.3 mm (AWG-16)
2
2
Installation plate
(Keep horizontal direction)