background image

ECO OPERATION

9

TEMPORARY OPERATION

12

In case of the misplaced or discharged remote control

 

Pressing the RESET button, the unit can start or 
stop without using the remote control.

 

Operation mode is set on AUTOMATIC operation, 
preset temperature is 24°C and fan operation is 
automatic speed.

TIMER OPERATION

10

Set the timer when the air conditioner is operating.

Setting the ON Timer

Setting the OFF Timer

1

Press 

  : Set the desired ON 

timer.

Press 

  : Set the desired 

OFF timer.

2

Press 

  : Set the timer.

Press 

  : Set the timer.

3

Press 

  : Cancel the timer.

Press 

  : Cancel the timer.

Daily timer allows the user to set both the ON & OFF timers and will be 
activated on a daily basis.

Setting Daily Timer

1

Press 

 : Set the ON timer.

3

Press 

.

2

Press 

 : Set the OFF timer.

4

Press 

 button during 

the (  or  ) mark 

fl

 ashing.

 

During daily timer is activating, both arrows ( ,  ) are indicated.

Note:

 

Keep the remote control in accessible transmission to the indoor unit; 
otherwise, the time lag of up to 15 minutes will occur.

 

The setting will be saved for the next same operation.

PRESET OPERATION

13

Set your preferred operation for future use. The setting will be memorized by 
the unit for future operation (except air

fl

 ow direction).

1. Select your preferred operation.

2. Press and hold 

 for 3 seconds to memorize the setting.

The 

P

 mark displays.

3. Press 

 : Operate the preset operation.

AUTO RESTART OPERATION

14

To automatically restart the air conditioner after the power failure (Power of 
the unit must be on.)

Setting

1.  Press and hold the RESET button on the indoor unit for 3 seconds 

to set the operation. (“Pi Pi Pi” sound and OPERATION lamp blink 5 
times/sec for 5 seconds)

2.  Press and hold the RESET button on the indoor unit for 3 seconds to 

cancel the operation. (“Pi Pi Pi” sound but OPERATION lamp does not 
blink) 

 

In case of ON timer or OFF timer are set, AUTO RESTART 
OPERATION does not activate.

For comfortable sleep, automatically control air 

fl

 ow and automatically turn 

OFF.

Press 

 : Select 1, 3, 5 or 9 hrs for OFF timer operation.

Note:

 The cooling operation, the set temperature will increase automatically 

1 degree/hour for 2 hours (maximum 2 degrees increase). For heating 
operation, the set temperature will decrease.

COMFORT SLEEP OPERATION

15

SELF CLEANING OPERATION 
(COOL AND DRY OPERATION ONLY)

16

To protect bad smell caused by the humidity in the indoor unit.

1. If the 

 button is pressed once during “Cool” or “Dry” mode, 

the fan will continue to run for other 30 minutes, then it will turn off 
automatically. This will reduce the moisture in the indoor unit.

2.  To stop the unit immediately, press the 

 more 2 times 

within 30 seconds.

DISPLAY LAMP BRIGHTNESS ADJUSTMENT

11

To decrease the display lamp brightness or turn it off.

1.  Press and hold 

)$1

 for 3 seconds until brightness level (

 or 

) is shown on remote control LCD then release the button.

2. Press 

Rise

 or 

Decrease

  to adjust brightness in 4 levels.

Remote control 

LCD

Operation display

Brightness

 

Lamp illuminates full brightness.

100%

Lamp illuminates 50% brightness.

50%

Lamp illuminates 50% brightness and the 
operation lamp is turned off.

50%

All lamps are turned off.

All turned off

 

In the examples of 

 and 

, the lamp illuminates for 5 seconds before 

going off.

 Firstly, turn off the circuit breaker.

Indoor Unit and Remote Control

 

Clean the indoor unit and the remote control with a wet cloth when 
needed.

 

No benzine, thinner, polishing powder or chemically-treated duster.

Air 

fi

 lters

Clean every 2 weeks.

1. Open the air inlet grille.
2. Remove the air 

fi

 lters.

3. Vacuum or wash and then dry them.
4. Reinstall the air 

fi

 lters and close the air inlet grille.

MAINTENANCE

17

To automatically control room to save energy (except in DRY and FAN ONLY 
mode)

Press 

 : Start and stop the operation.

Note:

 Cooling operation; the set temperature will increase automatically 1 

degree/hour for 2 hours (maximum 2 degrees increase). For heating 
operation the set temperature will decrease.

EN

Содержание RAS-18PAVSG-E

Страница 1: ...ENGLISH ENGLISH OWNER S MANUAL R32 1120650201 AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS 18 22 24PKVSG E Outdoor unit RAS 18 22 24PAVSG E ...

Страница 2: ...expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner and disconnect the power supply or turn off the breaker This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of ex...

Страница 3: ...appliance in kg h0 is the installation height of the appliance in m 0 6 m for floor standing 1 8 m for wall mounted 1 0 m for window mounted 2 2 m for ceiling mounted For these units recommend installation height 2 5 m CAUTION Do not wash the unit with water It may cause an electric shock Do not use this air conditioner for other purposes such as preserving food breeding animal etc Do not step or ...

Страница 4: ...FORT SLEEP Filter reset button FILTER Set clock button CLOCK Check button CHECK Reset button RESET AUTOMATIC OPERATION 5 To automatically select cooling heating or fan only operation 1 Press 02 Select A 2 Press Set the desired temperature 3 Press 1 Select AUTO LOW LOW MED MED HIGH or Quiet 1 Press 02 Select Cool Heat or Fan only 2 Press Set the desired temperature Cooling Min 17 C Heating Max 30 C...

Страница 5: ...does not activate For comfortable sleep automatically control air flow and automatically turn OFF Press Select 1 3 5 or 9 hrs for OFF timer operation Note The cooling operation the set temperature will increase automatically 1 degree hour for 2 hours maximum 2 degrees increase For heating operation the set temperature will decrease COMFORT SLEEP OPERATION 15 SELF CLEANING OPERATION COOL AND DRY OP...

Страница 6: ...et Remote Control to be A 2 Remote Control A has not A display 3 Default setting of Remote Control from factory is A 1 Three minute protection feature To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON 2 Preheating operation Warm up the unit for 5 minutes before the heating operation starts 3 Warm air control When the room temperature reaches the set t...

Страница 7: ...1120650201 ...

Отзывы: