AIR CONDITIONER 

(SPLIT TYPE)

INSTALLATION MANUAL

For general public use

Indoor Unit

Outdoor Unit

RAS-07PKVP-E
RAS-10PKVP-E
RAS-13PKVP-E
RAS-16PKVP-E
RAS-18PKVP-E

RAS-07PKVP-ND
RAS-10PKVP-ND
RAS-13PKVP-ND
RAS-16PKVP-ND
RAS-18PKVP-ND

RAS-07PAVP-E
RAS-10PAVP-E
RAS-13PAVP-E
RAS-16PAVP-E
RAS-18PAVP-E

RAS-07PAVP-ND
RAS-10PAVP-ND
RAS-13PAVP-ND
RAS-16PAVP-ND
RAS-18PAVP-ND

Содержание RAS-18PAVP-E

Страница 1: ... Unit Outdoor Unit RAS 07PKVP E RAS 10PKVP E RAS 13PKVP E RAS 16PKVP E RAS 18PKVP E RAS 07PKVP ND RAS 10PKVP ND RAS 13PKVP ND RAS 16PKVP ND RAS 18PKVP ND RAS 07PAVP E RAS 10PAVP E RAS 13PAVP E RAS 16PAVP E RAS 18PAVP E RAS 07PAVP ND RAS 10PAVP ND RAS 13PAVP ND RAS 16PAVP ND RAS 18PAVP ND ...

Страница 2: ...DOOR UNITS 4 3 OPTIONAL PARTS ACCESSORIES AND TOOLS 5 4 INSTALLATION OF INDOOR UNIT 7 5 INSTALLATION OF OUTDOOR UNIT 14 6 TEST OPERATION 18 7 REMOVING THE MAIN PARTS 19 Please read this installation manual carefully before installing the air conditioner CONTENTS ENGLISH ...

Страница 3: ...rmer refrigerant or refrigerating machine oil does not enter the refrigeration cycle of a new refrigerant air conditioner To avoid mixing refrigerant and refrigerating machine oil the sizes of charging port connecting sections on the main unit are different from those for the conventional refrigerant and different size tools are also required For connecting pipes use new and clean piping materials...

Страница 4: ...eak If there is any gas leakage or accumulation around the unit it can cause a fire Do not select a location for installation where there may be excessive water or humidity such as a bathroom Deterioration of insulation may cause electrical shock or fire Installation work must be performed following the instructions in this installation manual Improper installation may cause water leakage electric...

Страница 5: ... Request the user to keep the place around the unit tidy and clean Make sure to conduct a trial operation after the installation work and explain how to use and maintain the unit to the customer in accordance with the manual Ask the customer to keep the operation manual along with the installation manual REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER Please make absolutely sure that the install...

Страница 6: ...ottom right or bottom left as shown below Extension drain hose 8 mm thick heat resisting polyethylene foam 80 mm or more only when unobstructed to the front and both sides d Remote controller holder f Remote controller holder mounting screw For the rear left and left piping Wall Do not allow the drain hose to become slack Cut the piping hole slightly sloped With the remote controller cover removed...

Страница 7: ...uts If it is necessary to drain the defrost water attach drain nipple to the base plate of the outdoor unit before installing it Accessory and Installation Parts Part No Part name Q ty Part No Part name Q ty Part No Part name Q ty a Installation plate x 1 d Remote controller holder x 1 g Drain nipple x 1 b Wireless remote controller x 1 e Mounting screw φ4 x 25L x 7 h Water proof rubber cap x 2 c ...

Страница 8: ...ng charged the port diameters have been changed Charge hose In order to increase pressure resisting strength hose materials and port sizes have been changed to 1 2 UNF 20 threads per inch When purchasing a charge hose be sure to confirm the port size Electronic balance for refrigerant charging As working pressure is high and gasification speed is fast it is difficult to read the indicated value by...

Страница 9: ...e remote controller should be determined as shown below Drilling When installing the refrigerant pipes from the rear 1 Decide the installation plate mounting position on the wall 2 Mark the corresponding pipe hole wall positions according to the positioning marks on the installation plate 3 Drill the pipe holes Dia 65 mm or Dia 80 mm slightly slanted downward to the outside NOTE When drilling into...

Страница 10: ...ng sure all four corners are secure 1 The supply voltage must be the same as the rated voltage of the air conditioner 2 Prepare a power source for the exclusive use of the air conditioner NOTE Wire type H07RN F or 60245IEC66 1 0 mm2 CAUTION When installing the installation plate with mounting screws do not use anchor bolt holes Otherwise the unit may fall down and result in personal injury and pro...

Страница 11: ...nnecting cable fully into the terminal block and secure it tightly with screws Make a loop with the earth wire under the terminal block and secure it with the earth screw 6 Tightening torque 1 2 N m 0 12 kgf m 7 Secure the connecting cable with the cord clamp 8 Attach the terminal cover and moving panel on the indoor unit NOTE Connecting cable Indoor unit outdoor unit Wire type H07RN F or 60245IEC...

Страница 12: ...in hose then pull out the drain hose How to attach the drain cap 1 Insert hexagonal wrench 4 mm 2 Firmly insert drain cap How to attach the drain hose Insert the drain hose firmly until the connector contacts the insulation then secure it in place using the original screw Piping and Drain Hose Installation Always use the original screw that secured the drain hose to the unit Using a different scre...

Страница 13: ... them Outer diameter Bending radius 6 35 mm 30 mm 9 52 mm 40 mm 12 7 mm 50 mm CAUTION Bind the auxiliary pipes two and connecting cable with facing tape tightly In case of leftward piping and rear leftward piping bind the auxiliary pipes two only with facing tape Carefully arrange the pipes so that none of the pipes stick out of the rear plate of the indoor unit Carefully connect the auxiliary pip...

Страница 14: ...ate 3 While pressing the indoor unit onto the wall hook it at the lower part on the installation plate Pull the indoor unit toward you to confirm that it is firmly hooked on the installation plate For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing the bottom up at the specified places Indoor Unit Installation Hook here a Installation plate Hook ...

Страница 15: ...lected from condensation which forms on the back of the indoor unit to the drain pan Therefore do not locate the power cord and other parts at a height above the drain guide Drainage CAUTION Install the drain pipe for proper drainage Improper drainage can result in water dripping inside the room Do not put the drain hose end into water Do not route the drain hose upwards Do not form the drain hose...

Страница 16: ...ntralized drain is required when installing the unit on a balcony or wall follow the steps below to drain off the water 1 Proceed with water proofing by installing the water proof rubber caps h in the 2 elongated holes on the base plate of the outdoor unit How to install the water proof rubber caps 1 Place four fingers into each cap and insert the caps into the water drain holes by pushing them in...

Страница 17: ...eful for adjusting projection margin size Tighten the connection Align the centers of the connecting pipes and tighten the flare nut as much as possible with your fingers Then tighten the nut with a wrench and torque wrench as shown in the figure Refrigerant Piping Connection Outer diameter of copper pipe R410A tool used Conventional tool used 6 35 0 to 0 5 1 0 to 1 5 9 52 0 to 0 5 1 0 to 1 5 12 7...

Страница 18: ...ters assuming a pump capacity of 27 liters per minute Confirm that the compound pressure gauge reading is 101 kPa 76 cmHg 5 Close the low pressure valve handle of gauge manifold 6 Open fully the valve stem of the packed valves both sides of Gas and Liquid 7 Remove the charging hose from the service port 8 Securely tighten the caps on the packed valves Outer diameter of copper pipe Tightening torqu...

Страница 19: ... RAS 07PKVP E RAS 07PKVP ND RAS 10PKVP E RAS 10PKVP ND RAS 13PKVP E RAS 13PKVP ND RAS 16PKVP E RAS 16PKVP ND RAS 18PKVP E RAS 18PKVP ND Power source 220 240 V 50 Hz 220 230 V 60 Hz Maximum running current 9 5 A Installation fuse rating 16 A breaker or fuse all types can be used Power cord H07RN F or 60245IEC66 1 5 mm2 Connecting cable Wire type H07RN F or 60245IEC66 1 0 mm2 CAUTION Incorrect wirin...

Страница 20: ...not accepted 1 Setting the remote controller a Slide open the remote controller cover and remove the batteries b Cut the jumper wire inside the battery compartment using nippers The jumper wire should not remain in contact after being cut Also be careful not to let plastic scraps jumper wire cuttings or other debris enter the inside of the remote controller c Insert the batteries B appears in the ...

Страница 21: ...l 3 Insert your thumb into the air outlet bottom section and lift up the front panel bottom 4 Close the moving panel to remove the clips on the top side as shown below Press your finger down on the clip on the front panel top and lift up the panel back edge so that the clip is released 5 locations 7 REMOVING THE MAIN PARTS CAUTION Before removing the front panel moving panel or air flow louvers be...

Страница 22: ... the right side 1 screw 3 After removing a screw of the left side panel stopper slide the panel stopper downwards 4 Grasp both sides of the moving panel return the panel support to its original position and press the left side arm inwards with your finger 5 Pull out the moving panel towards the left side to remove Lead wire cover Screw Panel stopper Screw ...

Страница 23: ...rt the right side joint first 2 Insert the left side joint raise the panel stopper upwards and secure with the screw 3 Insert the top edge of the lead wire cover into the front panel and secure with a screw Left side joint Right side joint Panel stopper Screw Screw Lead wire cover ...

Страница 24: ...ir flow louvers by inserting the connector joints in the order of left right and center 2 Secure the horizontal air flow louvers to the connector joints After pressing in the connector joints align the positions of the connector joints and connectors Press the louver fixture downwards to lock it into place After attaching move the louver fixture from side to side to check that the connector joint ...

Страница 25: ......

Страница 26: ...EG44550301 ...

Отзывы: