Check the flare nut connections for the gas leak with
a gas leak detector or soap water.
Fig.
10
-
6
-1
10-
6
. Others
10-
6
-1
. Gas leak test
Check places
for outdoor unit
Check places for
indoor unit (Flarenut
connection)
• When two indoor units are installed in the
same room or adjacent two rooms, if operating
a unit, two units may receive the remote
control signal simultaneously and operate. In
this case, the operation can be preserved by
setting either one remote control to B setting.
(Both are set to A setting in factory shipment.)
• The remote control signal is not received when
the settings of indoor unit and remote control
are different.
• There is no relation between A setting/B
setting and A room/B room when connecting
the piping and cables.
To separate using of remote control for each
indoor unit in case of 2 air conditioner are
installed near.
Remote Control B Setup.
1. Press [RESET] button on the indoor unit to
turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on the Remote
Control by the tip of the pencil. “00” will be
shown on the display (Picture
1
).
4. Press [MODE] during pushing [CHECK]. “B”
will show on the display and “00” will disappear
and the air conditioner will turn OFF. The
Remote Control B is memorized (Picture
2
).
Note : 1. Repeat previous step to reset Remote
Control to be A.
2. Remote Control A have not “A” display.
3. Default setting of Remote Control from
factory is A.
10-
6
-2
. Remote Control A-B Selection
1
2
Adhesion of B label (When setting to B)
•
Be sure to adhere the B label
#
on the cover
terminal same as the below figure.
For RAS-B05, 07, 10, 13, 16E2KVG-E
10
-
6
-3. Test operation
To switch the TEST RUN (COOL) mode, press
[RESET] button for 10 sec. (The beeper will make
a short beep.)
OPERATION /
RESET Button
Fig.
10
-
6
-
4
B
Cover terminal
B Label
Fig.
10
-
6
-
3
Fig.
10
-
6
-
2
- 80 -