ELECTRICAL WORKS
The power supply can be selected to connect to indoor unit or outdoor unit. Choose proper way and connect the power supply and connecting cable by follow
the instruction as following.
Model
05k
07k
10k
13k
16k
18k
Power source
50Hz, 220 – 240 V Single phase
Maximum running current
5.0A
5.4A
7.2A
7.4A
9.0A
9.25A
Circuit breaker rating
6.5A
7.0A
9.0A
9.5A
11.5A
12.0A
Power supply cable
H07RN-F or 60245 IEC66 (1.5 mm
2
or more)
H07RN-F or 60245 IEC66
(2.5 mm
2
or more)
Connecting cable
H07RN-F or 60245 IEC66 (1.5 mm
2
or more)
Wiring Connection
Indoor unit
Wiring of the connecting cable can be carried out without removing the
front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local cords) into the pipe
hole on the wall.
4. Take out the connecting cable through the cable slot on the rear panel so
that it protrudes about 20 cm from the front.
5. Insert the connecting cable fully into the terminal block and secure it
tightly with screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor
unit.
Air inlet grille
Front panel
Screw
Screws
Terminal cover
Cord clamp
How to install the air inlet grille on the indoor
unit
• When attaching the air inlet grille, the contrary of the removed operation is
performed.
Outdoor unit
1. Remove the valve cover, the electric parts cover and the cord clamp from
the outdoor unit.
2. Connect the connecting cable to the terminal as identified by the
matching numbers on the terminal block of indoor and outdoor unit.
3. Insert the power cord and the connecting cable carefully into the terminal
block and secure it tightly with screws.
4. Use vinyl tape, etc. to insulate the cords which are not going to be used.
Locate them so that they do not touch any electrical or metal parts.
5. Secure the power cord and the connecting cable with the cord clamp.
6. Attach the electric parts cover and the valve cover on the outdoor unit.
Terminals block
Valve cover
11
1122950109_S04_182x257_52p_S_p70_18TR+RU.indd 13
12/25/2018 10:46:57 AM
Содержание RAS-16TAVG-EE
Страница 49: ...MEMO 1122950109_S04_182x257_52p_S_p70_181217_EN TR RU indd 49 12 25 2018 10 47 23 AM ...
Страница 50: ...MEMO 1122950109_S04_182x257_52p_S_p70_181217_EN TR RU indd 50 12 25 2018 10 47 23 AM ...
Страница 51: ...1122950109_S04_182x257_52p_S_p70_181217_EN TR RU indd 51 12 25 2018 10 47 23 AM ...
Страница 52: ...1122950109 1122950109_S04_182x257_52p_S_p70_181217_EN TR RU indd 52 12 25 2018 10 47 23 AM ...