6-1. Indoor Unit
No.
Parts name
Type
Specifications
RAS-10,13SKV2-E AFN-220-20-4D AC 240V, 20W
RAS-16SKV2-E ICF-340-30-4 DC 340V, 30W
2 Room temp. sensor (TA-sensor)
( - )
10k
Ω
at 25
°
C
3 Heat exchanger temp. sensor (TC-sensor)
( - )
10k
Ω
at 25°C
4
Louver motor
MP24Z3T
Output (Rated) 1W, 16 poles, DC12V
6-2. Outdoor Unit
No.
Parts name
Type
Specifications
RAS-16SAV2-E CH-57 L = 10mH, 16A
RAS-10,13SAV2-E CH-69 L = 19mH, 10A
2
Outdoor fan motor
ICF-140-43-4R
DC140V, 43W
3 Suction temp. sensor (TS sensor)
(Inverter attached) 10k
Ω
(25°C)
4 Discharge temp. sensor (TD sensor)
(Inverter attached) 62k
Ω
(20°C)
5 Outside air temp. sensor (TO sensor)
(Inverter attached) 10k
Ω
(25°C)
6 Heat exchanger temp. sensor (TE sensor) (Inverter attached) 10k
Ω
(25°C)
Reactor
1
1
Fan motor
(for indoor)
20A, AC250V
RAS-10,13SAV2-E
DA89X1C-23FZ2
RAS-16SAV2-E
DA111A1F-20F1
CAM-MD12TCTH-2
STF
3-phases 4-poles 750W
DC12V
AC220-240V
Coil for 4-way valve
COIL FOR P.M.V.
Compressor
Terminal block (5P)
7
8
9
10
6. SPECIFICATIONS OF ELECTRICAL PARTS
FILE NO. SVM-10001