![Toshiba RAS-10UA-AS2 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/toshiba/ras-10ua-as2/ras-10ua-as2_service-manual_1135586014.webp)
– 13 –
FILE NO. SVM-03001
4-3. Outdoor Unit (RAS-10UAH-ES2, RAS-10UAH-AS2)
No.
Parts name
Type
Specifications
Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz
1
Compressor
PA108X1T-4FZ1
Winding resistance (
Ω
)
C-R
C-S
(at 20°C)
3.89
4.51
Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50Hz
2
Fan motor (for outdoor)
HF-240-30B
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20°C)
245
388.3
3
Running capacitor
DS451155BPQC
AC 450V, 1.5
µ
F
(for fan motor)
4
Running capacitor
DS371256CPNB
AC 370V, 25
µ
F
(for compressor)
5
Solenoid coil
SQ-373
AC 220 – 240V
(for 4-way valve)
4-4. Indoor Unit (RAS-13UKP-ES2, RAS-13UKP-AS2, RAS-10UKP-ES2,
RAS-10UKP-AS2)
No.
Parts name
Type
Specifications
1
Fan motor (for indoor)
MMF-240-20-4A-1
AC Motor with 135°C thermo fuse
2
Thermo sensor (TA-sensor)
———
10k
Ω
at 25°C
3
Switching transformer (T01)
SWT-47
4
Microcontroller unit (IC30)
TMP87CM40AN-2C67
5
Heat exchanger sensor
———
10k
Ω
at 25°C
(TC-sensor)
6
Line filter (L01)
LC*SS11V-06270
27mH, 600mA
7
Bridge rectifier (DB01)
D3SBA60
4A, 600V
8
Capacitor (C02)
KMH400VSSN47M22S
47
µ
F, 400V
9
Fuse (F01)
TSCR6.3A
T6.3A, 250VAC
10
Varistor (R21, R22)
15G561K
560V
11
Resistor (R01)
RF-2TK5R6
5.6
Ω
, 2W
12
Louver motor
MP24GA
12VDC
13
Relay (Comp., RY01)
DI12D1
Rating 20A/AC250V, 12VDC