10-5-
2
.
Power Supply and Connecting Cable Connection
Power Supply Input at Indoor Unit Terminal Block (Recommend)
Indoor Unit
Outdoor Unit
Power supply cable
connect to
L
N
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Power supply cable
Stripping length of the power
supply cable
N
L
Earth line
50 mm
10 mm
70 mm
10 mm
Connecting cable
Earth line
Connecting
cable
Terminal block
Connecting cable
connect to
1
2
3
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Connecting
cable
Earth line
Connecting
cable
Stripping length of the
connecting cable
3
50 mm
Earth line
10 mm
70 mm
10 mm
Power Supply Input at Outdoor Unit Terminal Block (Optional)
Outdoor Unit
Indoor Unit
Connecting cable
connect to
L
2
3
Terminal block (L N 1 2 3)
Earth line
Connecting cable
Connecting cable
Stripping length of the
connecting cable
3
2
L
Earth line
50 mm
10 mm
70 mm
10 mm
Connecting cable
Earth line
Earth line
Connecting cable
Power cord
Terminal block
Power cord
1.
The power supply must be same as the rated of air conditioner.
2.
Prepare the power source for exclusive use with air conditioner.
3.
Circuit breaker must be used for the power supply line of this air conditioner.
4.
Be sure to comply power supply and connecting cable for size and wiring method.
5.
Every wire must be connected fi rmly.
6.
Perform wiring works so as to allow a general wiring capacity.
7.
Wrong wiring connection may cause some electrical part burn out.
8.
Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9.
This product can be connected to main power supply.
Connection to
fi
xed wiring : A switch which disconnects all poles and has a contact separation at least 3mm must be
incorporated in the
fi
xed wiring.
CAUTION