FILE NO. SVM-04004
5-
5
. RAS-10UKP-E
3
/ RAS-10UA-E
3
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
PH102T1-4CH
Cooling
Mark ( ) means check points of Gas Leak.
O.D.:9.52 mm
O.D.:6.35 mm
Cooling
Packed valve
(
Æ
9.52)
Packed valve
(
Æ
6.35)
0.39 m
(Connecting pipe)
Æ
9.52
0.49 m
(Connecting pipe)
Æ
6.35
T1
P
Refrigerant
R22 : 0.65 kg.
Evaporator
Capillary tube
Æ
1.5 x 1000
l
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard
0.53
11.0
High
27/19
35/24
Cooling
Overload
0.62
16.0
High
32/23
43/26
Low temperature
0.48
5.0
Low
21/15
21/15
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Fan speed
(indoor)
50Hz
Note
·
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
RAS-10UKP
X3 / RAS-10UAX3