ECO OPERATION

9

To automatically control room to save energy (except in DRY and FAN ONLY 
mode)

Press 

 : Start and stop the operation.

Note:

 Cooling operation; the set temperature will increase automatically 1 

degree/hour for 2 hours (maximum 2 degrees increase).

TEMPORARY OPERATION

10

In case of the misplaced or discharged remote control

  Pressing the RESET button, the unit can start 

or stop without using the remote control.

  Operation mode is set on AUTOMATIC 

operation, preset temperature is 24°C and fan 
operation is automatic speed.

Set the timer when the air conditioner is operating.

Setting the OFF timer

1

Press 

OFF

 for enter OFF timer setting.

2

Press 

 for select desired OFF timer. (0.5 - 12 hrs)

3

Press 

OFF

 for set OFF timer.

4

Press 

OFF

 again for cancel OFF timer.

TIMER OPERATION

11

AUTO RESTART OPERATION

12

To automatically restart the air conditioner after the power failure (Power of 
the unit must be on.)

Setting

1.  Press and hold the RESET button on the indoor unit for 3 seconds to 

set the operation. (3 beep sound and OPERATION lamp blink 5 time/
sec for 5 seconds)

2.  Press and hold the RESET button on the indoor unit for 3 seconds to 

cancel the operation. (3 beep sound but OPERATION lamp does not 
blink) 
•  In case of ON timer or OFF timer are set, AUTO RESTART 

OPERATION does not activate.

SELF CLEANING OPERATION 
(COOL AND DRY OPERATION ONLY)

14

OPERATION AND PERFORMANCE

15

1.  Three-minute protection feature: To prevent the unit from being 

activated for 3 minutes when suddenly restarted or switched to ON.

2.  Some minor cracking sound may occur when unit operating. This is 

normal because the cracking sound may be caused by expansion/
contraction of plastic.

Air conditioner operating conditions

Temp.

Operation

Outdoor Temperature

Room Temperature

Cooling

15°C ~ 46°C

21°C ~ 32°C

Dry

15°C ~ 46°C

17°C ~ 32°C

The unit does not operate.

Cooling is abnormally low.

 The power main switch is 

turned off.

 The circuit breaker is 

activated to cut off the power 
supply.

 Stoppage of electric current

 ON timer is set.

 The 

fi

lters are blocked with dust.

 The temperature has been set 

improperly.

 The windows or doors are opened.

 The air inlet or outlet of the outdoor 

unit is blocked.

 The fan speed is too low.

 The operation mode is FAN or DRY.

TROUBLESHOOTING (CHECK POINT)

16

REMOTE CONTROL A-B SELECTION

17

To separate using of remote control for each indoor unit in case of 2 air 
conditioner are installed nearly.

Remote Control B Setup.

1.  Press RESET button on the indoor unit to turn the air conditioner ON.
2.  Point the remote control at the indoor unit.

3.  Push and hold 

 button on the Remote Control by the tip of the 

pencil. “00” will be shown on the display. (Picture 

1

)

4.  Press 

MODE

 during pushing 

. “B” will show on the display and 

“00” will disappear and the air conditioner will turn OFF. The Remote 
Control B is memorized. (Picture 

2

)

Note:

 1. Repeat above step to reset Remote Control to be A.

 

 

2. Remote Control A has not “A” display.

 

 

3. Default setting of Remote Control from factory is A.

 Firstly, turn off the circuit breaker.

Indoor Unit and Remote Control

  Clean the indoor unit and the remote control with a wet cloth when 

needed.

  No benzine, thinner, polishing powder or chemically-treated duster.

MAINTENANCE

13

To protect bad smell caused by the humidity in the indoor unit.

1. If the 

 button is pressed once during “Cool” or “Dry” mode, 

the fan will continue to run for other 30 minutes, then it will turn off 
automatically. This will reduce the moisture in the indoor unit.

2.  To stop the unit immediately, press the 

 more 2 times 

within 30 seconds.

RU

EN

1110255122_EN.indd   3

1110255122_EN.indd   3

1/12/2558 BE   11:36

1/12/2558 BE   11:36

Содержание RAS-07S3KS-EE

Страница 1: ...Й OWNER S MANUAL AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS 07 10S3KS EE Outdoor unit RAS 07 10S3AS EE 1110255122 1110255122_EN indd 1 1110255122_EN indd 1 1 12 2558 BE 11 36 1 12 2558 BE 11 36 ...

Страница 2: ...or remove the cover It may expose you to dangerous voltages Ask the dealer or the specialist to do this Turning off the power supply will not prevent potential electric shock The appliance shall be installed in accordance with national wiring regulation Means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fixed wiring WARNING...

Страница 3: ...ns Temp Operation Outdoor Temperature Room Temperature Cooling 15 C 46 C 21 C 32 C Dry 15 C 46 C 17 C 32 C The unit does not operate Cooling is abnormally low The power main switch is turned off The circuit breaker is activated to cut off the power supply Stoppage of electric current ON timer is set The filters are blocked with dust The temperature has been set improperly The windows or doors are ...

Страница 4: ... Управления 1 Удалите батарейку 2 Нажмите кнопку 3 Вставьте батарейку OПАCHO Не выполняйте установку ремонт не открывайте и не снимайте крышку Вы можете подвергнуться воздействию высокого напряжения Обратитесь по этому вопросу к дилеру или специалисту отключение питания не предотвращает опасность поражения электрическим током Прибор должен устанавливаться в соответствии с действующими внутри стран...

Страница 5: ...трескивающего звука может быть расширение сжатие пластика Условия работы кондиционера Температура Pежим Наружная температура Комнатная температура Охлаждение 15 C 46 C 21 C 32 C Сушка 15 C 46 C 17 C 32 C Устройство не работает Чрезвычайно низкая эффективность охлаждения Выключатель питания находится в положении OFF выключено Автоматический выключатель сработал и отключил подачу питания Прекращение...

Страница 6: ...MEMO 1110255122_RU indd 6 1110255122_RU indd 6 1 12 2558 BE 11 40 1 12 2558 BE 11 40 ...

Страница 7: ...MEMO 1110255122_RU indd 7 1110255122_RU indd 7 1 12 2558 BE 11 40 1 12 2558 BE 11 40 ...

Страница 8: ...1110255122 1110255122_RU indd 8 1110255122_RU indd 8 1 12 2558 BE 11 40 1 12 2558 BE 11 40 ...

Отзывы: