background image

Safety 

Precautions

 Page 9

Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will 
not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe 
components are the only types that can be worked on while live in the presence of a flammable 
atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts 
specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere 
from a leak.

8.Repair to intrinsically safe components 

 

and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % 
maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of 
detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and 
corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. 
If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from 
the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. 
Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the 
brazing process.  

When breaking into the refrigerant circuit to make repairs or for any other purpose conventional 
procedures shall be used. However, it is important that best practice is followed since flammability is a 
consideration. The following procedure shall be adhered to:
Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again with inert gas; Open the 
circuit by cutting or brazing.   

The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed 
with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or 

10.Detection of flammable refrigerants

The following leak detection methods are deemed acceptable for systems containing flammable 
refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity 
may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a 
refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for 
the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant 

11.Leak detection methods

Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or 
any other adverse environmental effects. The check shall also take into account the effects of aging or 
continual vibration from sources such as compressors or fans.

9.Cabling

12.Removal and evacuation

Under no circumstances shall potential sources of ignition be used in the searching for or detection 
of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.

 

being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an 
electrical supply to equipment during servicing, then a permanently operating form of leak detection 
shall be located at the most critical point to warn of a potentially hazardous situation. 
2)Particular attention shall be paid to the following to ensure that by working on electrical components, 
the casing is not altered in such a way that the level of protection is affected. This shall include damage 
to cables, excessive number of connections, terminals not made to original specification, damage to 
seals, incorrect fitting of glands, etc.  Ensure that apparatus is mounted securely. Ensure that seals or 
sealing materials have not degraded such that they no longer serve the purpose of preventing the 
ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer's 
specifications.
NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection 
equipment. Intrinsically safe components do not have to be isolated prior to working on them.

Содержание RACPD1212CRRC

Страница 1: ...ITIONER Local Air Conditioner Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference ...

Страница 2: ...recautions Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust Hose Installation Choosing The Right Location Tools Needed Accessories Window Installation Kit Installation Troubleshooting Tips 03 11 11 12 12 12 12 13 13 14 16 18 19 20 22 22 22 22 23 ...

Страница 3: ...s grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the nameplate of the unit Your unit must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker the fuse or circuit breake...

Страница 4: ...hould be supervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard CAUTION Disconnect the power if strange sounds smell or smoke ...

Страница 5: ... Wild disposal of waste in forests and landscapes endangers your health when hazar do us substances leak into the ground water and find their way into the food chain Do not use hazardous chemicals to clean or come into contact with the unit Do not use the unit in the presence of inflammable substances or vapour such as alcohol insecticides petrol etc Always transport your air conditioner in a vert...

Страница 6: ...el shall be carried out under the supervision of the person competent in the use of flammable refrigerants AVERTISSEMENT Ne pas utiliser de produits permettant d accélérer le dégel ou de produits de nettoyage autres que ceux recommandés par le fabricant L appareil doit être entreposé dans un endroit sans source d allumage fonctionnant en continu par exemple flamme nue appareil au gaz en marche ou ...

Страница 7: ...nside the package will not cause a leak of the refrigerant charge The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations 3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area around the workspace shall be s...

Страница 8: ...cuit is being used the secondary circuit shall be checked for the presence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a position where they are unlikely to be exposed 1 During repairs to sealed components all electrical supplies shall be disconnected from the ...

Страница 9: ...he following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may not be adequate or may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a potential source of ignition and is suitable for the re...

Страница 10: ...b Isolate system electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment is available and being used correctly The recovery process is supervised at all times by a competent person Recovery equipment and cylinders conform to the appropriate standards d Pump down refrigeran...

Страница 11: ...ly Installation Instructions Preparation NOTE All the illustrations in the manual are for explanation purpose only Your machine may be slightly different The actual shape shall prevail The unit can be controlled by the unit control panel alone or with the remote controller This manual does not include Remote Controller Operations see the Remote Controller Instruction packed with the unit for detai...

Страница 12: ... this could cause damage to the unit 50cm 19 7 inch 30cm 30cm 12inch 12inch 50cm 19 7inch Energy Rating Information The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts Diameter 150mm Length 1 5m Diameter 130mm Length 1 5m The Energy rating and noise information for unit with 3 meters extended exhaust duct is not assessed For some models NOTE We recommend that operating...

Страница 13: ...aving the air feeling damp To find the proper air conditioner determine the square footage of the room you want to cool by multiplying the room length by its width You also need to know the air conditioner s BTU British Thermal Unit rating which indicates the amount of heat it can remove from a room A higher Why is the cooling capacity lower on newer models than on older units number means more co...

Страница 14: ...ider A Bolt 1 pc 1 set Unit Adaptor Security Bracket and 2 Screws 1 pc 1 pc Exhaust Hose Drain Hose 1 pc 1 pc Window Slider Adaptor Power Cord Buckle O N O F F T E M P S H O R T C U T T IM E R O N T IM E R O F F M O D E FA N S LE E P S W IN G LE D 1 set 1 pc Window Slider B Remote Controller and Battery only for remote control models 1 pc Wall Exhaust Adaptor A only for wall installation models 2 ...

Страница 15: ...the Adjustable Window Slider or or Window slider A MODEL A MODEL B Window slider B Bolt Window slider A Window slider B Bolt MODEL A MODEL B MODEL C MODEL D 1 2 Window slider A Window slider B Window slider C Bolts Window slider A Window slider B Window slider C Bolts Bolt Bolt Bolt 1 2 3 1 2 1 2 3 Bolt Bolt Bolt 1 2 3 4 Bolt Bolt Bolt 1 4 Bolt Window Sliders After assembly Before assembly Window ...

Страница 16: ...em to the window sash and frame as shown 2 Insert the window slider assembly into the window opening Or Foam seal B Adhesive type shorter Foam seal A Adhesive type Foam seal B Adhesive type shorter Foam seal A Adhesive type Window slider A Window slider B if required Foam seal C Non adhesive type Or 2 Screws Security Bracket 3 Cut the non adhesive foam seal C strip to match the width or height of ...

Страница 17: ...the wall for the Wall Exhaust Adaptor B 2 Secure the Wall Exhaust Adaptor B to the wall using the four Anchors and Screws provided in the kit 3 Connect the Exhaust Hose Assembly with Wall Exhaust Adaptor A to the Wall Exhaust Adaptor B NOTE Cover the hole using the adaptor cap when not in use max 120cm or 47 inch min 30cm or 12 inch Expansion anchor position Adaptor cap Wall Exhaust Adaptor B VENT...

Страница 18: ...f WIRELESS light FOLLOW ME light Wireless light Used to initiate the Wireless function For the first time to use Wireless function press and hold the swing button for 3 seconds to initiate the Wireless connection mode The LED DISPLAY shows AP to indicate you can set Wireless connection If connection router is successful within 8 minutes the unit will exit Wireless connection mode automatically and...

Страница 19: ...When the function is turned on the constant fan light will illuminate identifying the fan continuous run for cooling When the function is turned off the constant fan light will go out identifying the fan cycle run with compressor stop Sleep Eco button Used to initiate the SLEEP ECO operation Power button Power switch on off LED display Shows the set temperature in C or F F no display for some mode...

Страница 20: ... Auto off stop program Press or hold the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The system will automatically revert back to display the previous temperature setting if there is no operation in a 5 seconds period Turning the unit ON or OFF at any time or adju...

Страница 21: ...out drain connector just attach the drain hose to the hole Place the open end of the Hose adaptor directly over the drain area in your basement floor that there are no kinks that will stop the warter flowing Place the end of the hose into the drain and make sure the end of the hose is down to let the water flow smoothly See Figs with Do never let it up See Figs with When the continuous drain hose ...

Страница 22: ...unit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold Turn off the appliance and unplug it Clean the air filter according to the instructions in the previous section Reinstall the clean dry filter before storing Remove the batteries from the r...

Страница 23: ... possible The unit is noisy and vibrates too much The unit makes a gurgling sound The ground is not level Place the unit on a flat level surface The air filter is blocked with dust or animal hair Turn off the unit and clean the filter according to instructions This sound is caused by the flow of refrigerant inside the unit This is normal Impedance Information To be in compliance EN 61000 3 11 the ...

Страница 24: ...n and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version ...

Страница 25: ......

Страница 26: ...明书为单英文版本 不含型号及商标 也无制造商信息 请业务根据所 销售国家或者区域的法规要求 使用对应的官方语言版本 增加型号及其它 法规要求信息 重新申请订单编码说明书 3 基准说明书的显示标贴为PD全功能 包含了目前已有的所有图标和功能按键及其 操作说明 请业务和技术支持根据订单实际的显示标贴对说明书的显示标贴进行替换 对图标和功能及其说明进行相应删减 4 P22页ImpedanceInformation内容只适合部分由于电压波动和闪烁不合格要求增加阻抗声明 机型 其它无不合格要求的机型可以直接删除此内容 如保留制单要将美的市场型号 改为客户型号 5 后面的选配页面标明了对应的不同冷媒 可燃冷媒与非可燃冷媒 下要修改的内容 ...

Страница 27: ...当机型为非可燃冷媒机型时 请进行以下变更 删除Pg6 Pg10 WARNING for Using R32 R290 Refrigerant 内容 ...

Отзывы: