– 4 –
FILE NO. SVM-06049
3. SPECIFICATIONS OF ELECTRICAL PARTS
3-1. RAC-18GE2B/18G2B/18G2L
No. Parts name
Code
Specifications
Output (Rated) 1,500W, 2 poles, Single phase, 208/230V, 60Hz
1 Compressor RM6520GPH96 Winding resistance (
Ω
)
Red-Black White-Black
(at 20°C)
1.029 1.841
Output (Rated)
150
W, 6 poles, Single phase, 220
-230
V, 60Hz
2 Fan motor
FG-230-150B
Winding resistance (
Ω
) Red-Black White-Black
(at 20°C)
22
.0
6 37
.
07
3 Auto louver motor 50SM16-54S
Output (Rated) 3W or less, 8 poles, Single phase, 220-240V, 50/60Hz
Winding resistance (k
Ω
) (at 20°C) 10.5
Room thermostat
Differential 2°C
YTB-T321
Rated current 20A (at 250V)
4
(RAC-18
GE2B
)
Closing current 80A (at 250V)
Room thermostat
Differential 2°C
(RAC-18
G
-AR/18
G
2B/ B-A106
Rated current 25A
18
G
2L) Closing current 90A
Selector switch
Rated current 3A (at 250V) between terminal 1-2, 3-4, 9-10
2137
Rated current 25A (at 250V) between terminal
}
5-6, 11-12
5
(RAC-18
G
E2B)
Closing current 100A (at 250V) between terminal
5-6, 11-12
Selector switch
Rated current 3A (at 250V) between terminal 1-2, 1-3
(RAC-18
G
-AR/18
G
2B/
2105B
18
G
2L) Rated current 25A (at 250V) between terminal 5-6, 1-4
6
Running
for fan motor
DS451
5
0
BPQD
5µ
F, 450V
capacitor
for compressor
R
S44
B506U0218S
50
µ
F, 440V
7
Auto louver switch 3019B-W Reated AC current, closing and cut-off current 250V, 3A
8
Heater (RAS-18
GE2B
) HG-2235
3.5kW, Thermal relay 60 ± 3°C OFF, 45 ± 5°C ON
Thermal fuse 85 °C ON
3-2. RAC-18G-AR
Different points from above model show below and another specifications are the same as above.
No. Parts name
Code
Specifications
Output (Rated) 1,500W, 2 poles, Single phase, 230V, 50Hz
1 Compressor
RM6523GNHE96 Winding resistance (
Ω
)
Red-Black White-Black
(at 20°C)
1.194 2.576
Output (Rated)
145
W, 6 poles, Single phase, 2
2
0
-240
V, 50Hz
2 Fan motor F
G
-2
4
0-
145A
Winding resistance (
Ω
) Red-Black White-Black
(at 20°C)
34
.
88 27.12
3
Running for fan motor
DS441805BPQJ
capacitor for compressor
RS44B606U0220S
8
µ
F , 440V
60
µ