Troubleshooting Procedures
PORTÉGÉ R700 Series Maintenance Manual (960-833) [CONFIDENTIAL]
2-35
2.6.2 Procedure 2 Message Check
When the power is turned on, the system performs the Initial Reliability Test (IRT) installed
in the BIOS ROM. When the test detects an error, an error message is displayed on the screen.
Make sure no floppy disk is in the FDD. Turn on the computer and check the message on the
screen. When an OS starts from the 2.5” HDD, go to Procedure 3. Otherwise, start with Check
1 below and perform the other checks as instructed.
Check 1 If any of the following messages appear, go to Procedure 3. If the following
messages do not appear, perform Check 2.
HDC ERROR
or
HDD #X ERROR
(After 5 seconds this message will disappear.)
Check 2 If either of the following messages appears, go to Check 3. If the following
messages do not appear, perform Check 4.
Insert system disk in drive
Press any key when ready .....
or
Non-System disk or disk error
Replace and press any key when ready
Check 3 Using the SYS command of the DOS, transfer the system to the 2.5” HDD. If the
system is not transferred, go to Procedure 3. Refer to the DOS Manual for detailed
operation.
If the following message appears on the display, the system program has been
transferred to the HDD.
System Transferred
If an error message appears on the display, perform Check 4.
Check 4 2.5” HDD(s) and the connector(s) of system board may be defective (Refer to the
steps described in Chapter 4,
Replacement Procedures
for disassembling.). Insert
HDD(s) to the connector(s) firmly. If it is (or they are) firmly connected, go to
Procedure 3.
Содержание PORTEGE R700 Series
Страница 12: ...1 Hardware Overview 1 2 CONFIDENTIAL PORTÉGÉ R700 Series Maintenance Manual 960 833 ...
Страница 41: ...1 Hardware Overview PORTÉGÉ R700 Series Maintenance Manual 960 833 CONFIDENTIAL 1 31 ...
Страница 47: ...Troubleshooting Procedures 2 2 PORTÉGÉ R700 Series Maintenance Manual 960 833 CONFIDENTIAL 2 ...
Страница 114: ...Tests and Diagnostics PORTÉGÉ R700 Series Maintenance Manual 960 833 CONFIDENTIAL 3 1 Chapter 3 Tests and Diagnostics ...
Страница 115: ...Tests and Diagnostics 3 2 CONFIDENTIAL PORTÉGÉ R700 Series Maintenance Manual 960 833 3 ...
Страница 289: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Страница 290: ...4 Replacement Procedures 4 ii CONFIDENTIAL PORTÉGÉ R700 Maintenance Manual 960 833 ...
Страница 294: ...4 Replacement Procedures 4 vi CONFIDENTIAL PORTÉGÉ R700 Maintenance Manual 960 833 ...
Страница 367: ...4 24 Cover assembly LCD assembly 4 Replacement Procedures PORTÉGÉ R700 Maintenance Manual 960 833 CONFIDENTIAL 4 73 ...
Страница 388: ...4 Replacement Procedures 4 28 Hinge 4 94 CONFIDENTIAL PORTÉGÉ R700 Maintenance Manual 960 833 ...
Страница 389: ... CONFIDENTIAL Appendices ...
Страница 390: ...Appendices App ii CONFIDENTIAL PORTÉGÉ R700 Series Maintenance Manual 960 833 ...
Страница 403: ...Appendices Appendix A Handling the LCD Module A 6 CONFIDENTIAL PORTÉGÉ R700 Series Maintenance Manual 960 833 ...
Страница 416: ...Appendix B Board Layout Appendices PORTÉGÉ R700 Series Maintenance Manual 960 833 CONFIDENTIAL B 13 ...
Страница 456: ...Appendices Appendix C Pin Assignments C 40 CONFIDENTIAL PORTÉGÉ R700 Series Maintenance Manual 960 833 ...
Страница 466: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL PORTÉGÉ R700 Series Maintenance Manual 960 833 ...
Страница 468: ...Appendices Appendix F Wiring diagrams F 2 CONFIDENTIAL PORTÉGÉ R700 Series Maintenance Manual 960 833 ...
Страница 470: ...Appendices Appendix G BIOS rewrite procedures G 2 CONFIDENTIAL PORTÉGÉ R700 Series Maintenance Manual 960 833 ...
Страница 472: ...Appendices Appendix H EC KBC rewrite procedures H 2 CONFIDENTIAL PORTÉGÉ R700 Series Maintenance Manual 960 833 ...
Страница 474: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL PORTÉGÉ R700 Series Maintenance Manual 960 833 ...