P9 ASD Installation and Operation Manual
225
Block Read Data 4
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network by
establishing the type of data to be read from the ASD of the communications
link.
See
for additional information on this parameter.
Direct Access Number — F878
Parameter Type —
Selection List
Factory Default —
None
Changeable During Run —
Yes
Block Read Data 5
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network by
establishing the type of data to be read from the ASD of the communications
link.
See
for additional information on this parameter.
Direct Access Number — F879
Parameter Type —
Selection List
Factory Default —
None
Changeable During Run —
Yes
Free Notes
Program
Communications
Communication Settings
This is an unused parameter that has allocated memory space.
The space may be used at the discretion of the user. This space may be used to
store information or a note to be transferred using communications.
Direct Access Number — F880
Parameter Type —
Numerical
Factory Default —
0
Changeable During Run —
Yes
Minimum — 0
Maximum — 65534
Network Option Reset Settings
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network by
establishing the targets of a Reset command received via the communications
link.
Settings:
0 — Reset ASD only
1 — Reset Option Board and ASD
Direct Access Number — F899
Parameter Type —
Selection List
Factory Default —
Reset ASD only
Changeable During Run —
Yes
Input Function Target 1
Program
My Function
My Function Unit 1
This parameter plays a role in the setup of the
My Function
feature by
selecting the functionality of the programmable
Input Function Target 1
terminal.
This setting assigns the function of the programmable
Input Function Target 1
terminal to any one of the user-selectable functions listed in
, or
See
for additional information on this parameter.
Direct Access Number — F900
Parameter Type —
Selection List
Factory Default —
0 (Disabled)
Changeable During Run —
Yes
Input Function Command 1
Program
My Function
My Function Unit 1
This parameter is used to assign a user-selected logical operator to two user-
selected
Input Function Target
variables, enable a counter/timer function, or
perform a hold/reset function.
lists the available selections. Their use and selection
requirements are described in an example at
.
Direct Access Number — F901
Parameter Type —
Selection List
Factory Default —
0 (NOP)
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......