214
P9 ASD Installation and Operation Manual
Trace Data 3
Program
Utilities
Trace
This parameter is used to select the
Trace Data 3
item from
to be read and stored in accordance with the setup of
and
.
See
for additional information on this parameter.
Direct Access Number — F744
Parameter Type —
Selection List
Factory Default —
Output Current
Changeable During Run —
Yes
Trace Data 4
Program
Utilities
Trace
This parameter is used to select the
Trace Data 4
item from
to be read and stored in accordance with the setup of
and
.
See
for additional information on this parameter.
Direct Access Number — F745
Parameter Type —
Selection List
Factory Default —
DC Voltage
Changeable During Run —
Yes
Baud Rate (RS485 2-Wire)
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network by
establishing the
Baud Rate
of the communications link.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (off then on)
for the changes to take effect.
Settings:
0 — 9600
1 — 19200
2 — 38400
Direct Access Number — F800
Parameter Type —
Selection List
Factory Default —
19200
Changeable During Run —
Yes
Units — bps
Parity (RS485 2- and 4-Wire)
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network by
establishing the
Parity
setting of the communications link.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (off then on)
for the changes to take effect.
Settings:
0 — No Parity
1 — Even Parity
2 — Odd Parity
Direct Access Number — F801
Parameter Type —
Selection List
Factory Default —
Even Parity
Changeable During Run —
Yes
ASD Number
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network by
assigning an identification (ID) number to each ASD in the communications
network.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (off then on)
for the changes to take effect.
Direct Access Number — F802
Parameter Type —
Numerical
Factory Default —
0
Changeable During Run —
Yes
Minimum — 0
Maximum — 247
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......