PID Deviation Lower-Limit
Program
Feedback
Feedback Settings
This parameter determines the maximum amount that the feedback may
decrease the output signal.
Direct Access Number — F365
Parameter Type —
Numerical
Factory Default —
60.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 60.00
Units — Hz
PID Feedback Differential (D) Gain
Program
Feedback
Feedback Settings
This parameter determines the degree that the
Differential
function affects the
output signal. The larger the value entered here, the more pronounced the affect
of the differential function for a given feedback signal level.
Direct Access Number — F366
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 2.55
Process Upper-Limit
Program
Feedback
Feedback Settings
Selecting
Process PID
at parameter
allows for this parameter setting to
function as the
Upper-Limit
while operating in the
PID Control
mode.
Direct Access Number — F367
Parameter Type —
Numerical
Factory Default —
60.00
Changeable During Run —
No
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
Process Lower-Limit
Program
Feedback
Feedback Settings
Selecting
Process PID
at parameter
allows for this parameter setting to
function as the
Lower-Limit
while operating in the
PID Control
mode.
Direct Access Number — F368
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
No
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
PID Control Delay
Program
Feedback
Feedback Settings
This parameter is used to delay the start of PID control at start up. During the
wait time set here, the ASD will follow the frequency control input of the
process value and the feedback input will be ignored until this setting times out,
at which time the PID setup assumes control.
Direct Access Number — F369
Parameter Type —
Numerical
Factory Default —
0
Changeable During Run —
Yes
Minimum — 0
Maximum — 2400
Units — Seconds
PID Output Upper-Limit
Program
Feedback
Feedback Settings
Selecting
Speed PID
at parameter
allows for this parameter setting to
function as the
Upper-Limit
while operating in the
PID Control
mode.
Direct Access Number — F370
Parameter Type —
Numerical
Factory Default —
60.00
Changeable During Run —
No
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......