ELECTRICAL ADJUSTMENTS
D3-1
1.
Read and perform these adjustments when repairing the
circuits or replacing electrical parts or PCB assemblies.
CAUTION
•
•
•
•
Use an isolation transformer when performing any service
on this chassis.
Before removing the anode cap, discharge electricity
because it contains high voltage.
When removing a PCB or related component, after
unfastening or changing a wire, be sure to put the wire
back in its original position.
When you exchange IC and Transistor with a heat sink,
apply silicon grease on the contact section of the heat
sink. Before applying new silicon grease, remove all the old
silicon grease. (Old grease may cause damages to the IC
and Transistor).
BEFORE MAKING ELECTRICAL
ADJUSTMENTS
Prepare the following measurement tools for
electrical adjustments.
1. Oscilloscope
2. Digital Voltmeter
3. Multi-sound Generator
4. Pattern Generator
On-Screen Display Adjustment
Unplug the AC plug for more than 5 seconds to set the
clock to the non-setting state. Then, set the volume level
to minimum.
Press the VOL. DOWN button on the set and the
Channel button (9) on the remote control for more than
2 seconds to appear the adjustment mode on the screen
as shown in Fig. 1-1.
1.
2.
Fig. 1-1
Use the Channel UP/DOWN button or Channel button
(0-9) on the remote control to select the options shown
in Fig. 1-2.
Press the MENU button on the remote control to end the
adjustments.
To display the adjustment screen for AV mode, press the
INPUT button on the remote control to set to the AV
mode. To display the adjustment screen for DVD mode,
press the DVD button on the remote control to set to the
DVD mode. Press the VOL.DOWN button on the set and
the channel (9) on the remote control for more than 2
seconds.
3.
4.
5.
TV
00 OSD H 05
FUNCTION
OSD H
OSD C
CUT OFF
H.POSI
H.BLK L
H.BLK R
V.SIZE
V.POSI
V.LIN
VS.CORR
V.COMP
R.BIAS
G.BIAS
B.BIAS
R.DRV
G.DRV
B.DRV
BRI CENT
NO.
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
FUNCTION
BRI MAX
BRI MIN
CONT CENT
CONT MAX
CONT MIN
COL CENT
COL MAX
COL MIN
TINT
SHARP
SUB BIAS
H.SIZE
PARABOLA
TRAPEZIUM
COR TOP
COR BTM
H.COMP
T.STE
NO.
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
Fig. 1-2
(VCR SECTION)
2-1: PG SHIFTER
1.
2.
3.
4.
Connect CH-1 on the oscilloscope to TP102 and CH-2 to
TP4201.
Playback the alignment tape.
Press both VOL. DOWN button on the set and the
Channel button (5) on the remote control for more than
2 seconds to set tracking to center.
Press the VOL. DOWN button on the set and the channel
button (3) on the remote control for more than 2
seconds until the indicator REC disappears. If the
indicator REC disappears, adjustment is completed.
(If the above adjustments doesn't work well:)
5.
6.
Press the VOL. DOWN button on the set and the channel
button (3) on the remote control for more than 2
seconds until the indicator REC disappears.
When the REC indicator is blinking, press both VOL.
DOWN button on the set and the channel button (4) on
the remote control for more than 2 seconds and adjust
the Tr/- button until the arising to the down of
Head Switching Pulse becomes 6.5
±
0.5H.
(Refer to Fig. 2-1-A, B)
Fig. 2-1-B
Fig. 2-1-A
2. BASIC ADJUSTMENTS
6.5H
CH-1
CH-2
6.5H
CH-2
CH-1