Part names

Hot water module

3

Part names and functions of the remote 

controller

Display section

All indicators are displayed in the display example below.   
Actually, only the selected options will be displayed.

 blinks on the display of the remote controller the first time the power 

switch is turned on.

• The initial settings progress while 

 is blinking. Start to use the remote 

controller after 

 has disappeared.

NOTE

The LCD may temporarily be blurred due to static electricity.

Electrical control box

Water outlet

Water inlet

Earth screw

Equipped on the electrical

control box

Drain pan

SET

TIME

TIMER SET

TEST

FILTER

RESET

TEMP.

CL

FAN

SAVE

SWING/FIX

VENT

MODE

ON / OFF

UNIT  LOUVER

Display 

section

Operation 

section

1

SETTING indicator

Displayed when setting the timer or other 
functions.

2

Operation mode indicator

Indicates the operation mode selected.

3

Error indicator

Displayed when the protective device activates or 
an error occurs.

4

Time display

Indicates time concerning the timer.
(Indicates an error code when an error occurs)

5

Timer mode indicator

Displays the timer mode.

6

TEST run indicator

Displayed during test run.

7

Set temperature display

The selected set temperature is displayed.

8

Pre-heat indicator

Displayed when defrost cycle is initiated.

9

No function indicator

Displayed when the function requested is not 
available on that model.

10

Central control indicator

Displayed when the air conditioner is controlled 
centrally and used with central control devices 
such as the central remote controller.
If the use of the remote controller is prohibited by 
the central control, 

 blinks when the ON/OFF, 

MODE, or TEMP. button on the remote controller 
is pushed, and the buttons do not function. 
(Settings that can be configured on the remote 
controller differ depending on the mode of the 
central control. For details, read the Owner’s 
Manual of the central remote controller.)

11

Operation mode controlled indicator

Displayed when the operation mode is restricted.

12

Operation ready display

This display appears on some models.

13

Service display

Displayed while the protective device works or an 
error occurs.

CAUTION

Remote controller sensor can not 

be used for the hot water module. 

Remote controller sensor has no 

function when remote controller 

is connected to the hot water 

module.

2

5

6

3

1

4

9

8

7

10

11

12

13

11-EN

12-EN

Содержание MMW-AP0271LQ-E

Страница 1: ...Indoor Unit Model name Hot Water Module MMW AP0271LQ E MMW AP0561LQ E HOT WATER MODULE MULTI TYPE Owner s Manual English For commercial use ...

Страница 2: ...igerant R22 in order to prevent destruction of the ozone layer This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the app...

Страница 3: ...rs including the hot water modules made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work Qualified service person The qualified service person is a person who installs repairs maintains relocates and removes the air conditioner...

Страница 4: ...ater module set the circuit breaker to the OFF position and contact a service person If you install the unit in a small room take appropriate measures to prevent the refrigerant from exceeding the limit concentration even if it leaks Consult the dealer from whom you purchased the hot water module when you implement the measures Accumulation of highly concentrated refrigerant may cause an oxygen de...

Страница 5: ... the circuit breaker to the OFF position and contact a qualified installer or a qualified service person to have the improvements or refitting done Do not set the circuit breaker to the ON position until the improvements or refitting is completed Do not customize the unit Doing so may result in fire electric shock etc Relocation When the hot water module is to be relocated do not relocate it yours...

Страница 6: ...se it may result in water leakage electric shock smoke emission and fire Do not put a water container such as a vase on the unit Water intrusion into the unit may occur and it may cause deterioration of electric insulation and result in electric shock 1 Refer to the Definition of Qualified Installer or Qualified Service Person Information on the transportation handling and storage of the carton Ex...

Страница 7: ... the timer mode 6 TEST run indicator Displayed during test run 7 Set temperature display The selected set temperature is displayed 8 Pre heat indicator Displayed when defrost cycle is initiated 9 No function indicator Displayed when the function requested is not available on that model 10 Central control indicator Displayed when the air conditioner is controlled centrally and used with central con...

Страница 8: ...OUVER 4 Basic operation When you use the hot water module for the first time or change the settings follow the procedures below From next time pushing the button starts running of the hot water module with the chosen settings Preparation Turn on the power switch When turned on the separation line appears and blinks on the remote controller display The remote controller will not work for about 1 mi...

Страница 9: ...quency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants Do not install the hot water module in locations where iron or other metal dust is present If iron or other metal dust adheres to or collects on the interior of the hot water module it may spontaneously combust and start a fire A failure may occur in certain locations such as the following Areas with ...

Страница 10: ...e controlled individually However indoor units connected to the same outdoor unit cannot perform cooling and heating simultaneously When you attempt simultaneous operation hot water module performing heating are stopped and the running preparation indicator is displayed on the remote controller An indoor unit performing cooling continues running When you attempt an operation without the configured...

Страница 11: ...nd by The pump and line heater operates for frost protection of water heat exchanger when water temperature decreases or outdoor unit start operation or refrigerant oil recovery control When power of the hot water module is turned on Ticktock sound is heard Sound is generated when the expansion valve operates when power has been turned on LCD blurs when it is touched LCD may temporarily blur by st...

Страница 12: ...in CODE No window Check code is displayed Indoor unit address in which an error occurred is displayed in UNIT No 2 Every pushing of button used to set temperature the error log stored in memory is displayed in order The numbers in CODE No indicate CODE No 01 latest to 04 oldest CAUTION Do not push button because all the error log of the indoor unit will be deleted 3 After confirmation push button ...

Страница 13: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Отзывы: