Remote controller model name: RBC-ASCU11-
LCD back-light lights for 15 seconds during remote controller operation.
All indicators are displayed in the display example below.
Actually, only the selected options will be displayed.
■
Operations
1
ON/OFF button
Turns on the unit when pushed, and turns off when pushed again.
2
Setting button
Sets setting temperature at the normal mode.
Changes each setting at the Operation mode, the Fan speed mode or the Wind direction mode.
3
OFF timer button
Setting the OFF timer.
4
Menu button
Selects the Operation mode select, the Fan speed select or the Wind direction select.
Each time you push the button, indicator is displayed as followings.
• The Fan speed select or the Wind direction select is not displayed depending on indoor unit models.
1
2
3
4
Operation lamp
Lights during operations.
Blinks when a check occurs or the
protective device activates.
Normal operation
mode
Operation mode
select
Fan speed select
Wind direction
select
■
Indicators
All icons on the display are shown for this explanation. Operations are not accepted when “SETTING” is flashing.
1
Operation mode indicator
Indicates the operation mode selected.
2
Central control indicator
Displayed when the air conditioner is controlled
centrally and used with central control devices
such as the central remote controller.
If the use of the remote controller is prohibited by
the central control,
blinks when the ON/OFF,
MODE, or TEMP. button on the remote controller
is pushed, and the buttons do not function.
(Settings that can be configured on the remote
controller differ depending on the mode of the
central control. For details, read the Owner’s
Manual of the central remote controller.)
3
Setting indicator
Indicates that the model is being checked
automatically after a breaker is thrown or some
other occurrence.
4
Service indicator
Displayed while the protective device works or a
check occurs.
5
Test run indicator
Displayed during test run.
6
Temperature setting indicator
The selected set temperature is displayed.
7
Swing indicator
Displayed during up/down movement of the
louvre.
8
Louvre position indicator
Indicates the louvre position.
9
Louvre lock indicator
Displayed when there is a louvre-locked unit.
10
Fan speed indicator
Indicates the selected fan speed
11
OFF timer indicator
When a trouble occurs, a check code is displayed.
12
Pre-heat indicator
Displayed when the heating mode is energized or
defrost cycle is initiated.
While this indication is displayed, the indoor fan
stops or operate in fan mode.
13
Operation standby indicator
Indicates that the Super Modular Multi System
cannot cool if a different indoor unit is heating or
cannot heat if one is cooling; and that the Super
Heat Recovery Multi cannot heat or cool because
the outside temperature is outside the operating
range.
14
Remote controller sensor indicator
Displayed while the sensor of the remote controller
is used.
15
Notice display
Displayed while notice code occurs.
2
3 4
5
6
10
15
11
12
13
7
8
1
9
14
Auto
Low
Low +
Medium
High
Fix