Display section

All indicators are displayed on the display example below for explanation. In 
reality, only the selected options will be displayed. Indications concerning 
controlling the Air to Air Heat Exchanger with DX Coil Unit are explained here. 
For indications concerning an air conditioner, refer to the owner's manuals 
supplied with the remote controller and the air conditioner. 

 blinks on the display of the remote controller when the power switch 

is turned on for the first time.
The initial settings progress while 

 is blinking. Start to use the remote 

controller after 

 has disappeared.

NOTE

The LCD may temporarily be blurred due to static electricity.

1

SETTING indicator

Displayed when setting the timer or other 
functions.

2

Operation mode indicator

Indicates the operation mode selected.

3

Error indicator

Displayed when the protective device activates or 
an error occurs.

4

Time indicator

Indicates time concerning the timer.
(Indicates a error code when an error occurs.)

5

Timer mode indicator

Each time you press the 

 button, the 

indication changes as follows: 

 

, and no timer indication.

6

Filter indicator

Reminder to clean the air filter.

7

Test run indicator

Displayed during a test run.

8

Louver position display (*1)

9

Swing indicator (*1)

10

Set temperature display

The selected set temperature is displayed.

11

Remote controller sensor indicator

Displayed when the remote controller sensor is 
used.

12

Pre-heat indicator

Displayed when the heating mode is energized or 
defrost cycle is initiated.
While this indication is displayed, the indoor fan 
stops or operate in fan mode.

13

No function indicator

Displayed when the function requested is not 
available on that model.

14

Fan speed indicator (*1)

Indicates the selected fan speed:

Display 

section

Operation 

section

2

5

3

4

8

10

7

9

6

1

11

13

12

14

(Auto)

(High)

(Medium)

(Low)

 

15

Louver Number display. (*1)

16

Power saving mode display

Displayed during capacity saving mode.

17

Louver lock indicator (*1)

18

UNIT No. indicator

The number of the Air to Air Heat Exchanger with 
DX Coil Unit selected using the UNIT button or that 
of the unit in which an error has occurred.

19

Central control indicator

Displayed when a central control device such as a 
central controller is also used. If the central control 
device prohibits the use of local remote 
controllers, 

 blinks when any of the 

 or TEMP. buttons are pressed and the 

operation is rejected.
The items controllable with the remote differ 
depending on the mode of central control. Refer to 
the owner's manual of the central control device 
you are using for more information

20

Operation mode controlled indicator

Displayed when MODE button is pushed while 
operation mode is fixed to cool or heat by the air 
conditioner administrator.

21

Operation ready display (*1)

This display appears on some models.

22

Service display

Displayed while the protective device works or a 
trouble occurs.

23

Ventilation fan speed indicator

Indicates the ventilation fan's speed. 

 or 

 is indicated. 

When the remote is used to control air 
conditioners together with the Air to Air Heat 
Exchanger with DX Coil Unit as a group, VENT 

FAN indicator appears (blinks) only when the 

 

button is pressed.

24

Ventilation mode indicator

Indicates the selected ventilation mode. 

 or 

 is indicated.

25

Nighttime heat purge indicator

Displayed during the nighttime heat purge 
operation. (*2)

26

Humidification indicator

Displayed during humidifying.

27

Ventilation indicator

If the remote is used to control the Air to Air Heat 
Exchanger with DX Coil Unit in a system linked 
with air conditioners, and separate operation of the 
unit is set to available, the indicator is displayed 
while the unit is running.
* The indicator is not displayed when the unit is 

running in a system equipped with only the Air to 
Air Heat Exchanger with DX Coil Unit.

(*1):
Not displayed. These functions are not available for Air 
to Air Heat Exchanger with DX Coil Unit.

(*2):
Displayed when these operation modes are activated.

22 19

18

20

17

23

27

21

24
25
26

16

15

(High)

(Low)

(SA > EA)

 (*2)

* Displayed when 

the setting is 
activated.

(SA < EA)

 (*2)

(Automatic mode)

(Heat exchange mode)

13-EN

14-EN

+00ET99915201_00Ta.book  Page 7  Tuesday, February 15, 2011  6:45 PM

Содержание MMD-VN1002HEXE

Страница 1: ...Coil Unit Model name Model with a humidifier MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE Model without a humidifier MMD VN502HEXE MMD VN802HEXE MMD VN1002HEXE Owner s Manual For commercial use Owner s Manual 1 English 00ET99915201_00Ta book Page 1 Tuesday February 15 2011 6 45 PM ...

Страница 2: ...roughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigeran...

Страница 3: ...g installation servicing and removal Use of a stand more than 50 cm high to clean the filter of the Air to Air Heat Exchanger with DX Coil Unit or to carry out other such jobs constitutes working at heights Due to the danger of falling off the stand and injuring yourself while working at heights this kind of work should not be done by unqualified individuals When this kind of work must be carried ...

Страница 4: ...erson 1 to refit the unit Do not set the circuit breaker to the ON position until the unit has been refitted Do not move or repair any unit by yourself Since there is high voltage inside the unit you may get electric shock when removing the cover and main unit Do not modify the products Do not also disassemble or modify the parts It may cause a fire electric shock or injury Relocation When the Air...

Страница 5: ...ndle with packing band or may get injured in case of broken band 2 cartons 91 kg 2 Part Names Air to Air Heat Exchanger with DX Coil Unit Separately sold parts Remote controller for the Air to Air Heat Exchanger with DX Coil Unit NRC 01HE SA Supply air RA Return air EA Exhaust air OA Outdoor air Inspection cover for the heat exchange element Earth screw in electrical control box Drain hole Connect...

Страница 6: ...X Coil Unit Outdoor unit Remote controller NRC 01HE RBC AMT32E Air conditioner Air conditioner Air to Air Heat Exchanger with DX Coil Unit Air to Air Heat Exchanger with DX Coil Unit When the Air to Air Heat Exchanger with DX Coil Unit system linked with indoor air conditioners is used set the Air to Air Heat Exchanger with DX Coil Unit as Follower referring to Setting the address manually using t...

Страница 7: ...he remote controller display after pushing the button 5 button Filter reset button Resets FILTER indication after cleaning 6 button Power save operation Use to initiate power saving mode Display section Operation section 1 3 5 2 6 4 7 button Swing Louver direction button 1 8 Operation lamp Lights up during operation Blinks when an error occurs or the protective device activates 9 button Turns on t...

Страница 8: ... mode 17 Louver lock indicator 1 18 UNIT No indicator The number of the Air to Air Heat Exchanger with DX Coil Unit selected using the UNIT button or that of the unit in which an error has occurred 19 Central control indicator Displayed when a central control device such as a central controller is also used If the central control device prohibits the use of local remote controllers blinks when any...

Страница 9: ... the outdoor air exhaustion Inflow of humidity and smells from the toilet and kitchen is reduced When SA EA is selected the volume of the outdoor air exhaustion is larger than that of the indoor air supply Outflow of smells and floating bacteria into a corridor or other places is reduced Consult your dealer if the setting of the air volume imbalance seems incorrect Changing ventilation mode 1 Push...

Страница 10: ...mount of time has passed between the nighttime heat purge operation becoming on standby and the monitoring operation starting The time is set between 1 48 hours in 1 hour steps 2 The indoor temperature is 3 C or more higher than the outdoor temperature and the indoor temperature is 2 C or more higher than the temperature set for the operation The conditions to pause the nighttime heat purge operat...

Страница 11: ...s Hours 7 Installation Location Do not install the unit in places where the outside temperature falls below 5 C Avoid installing near machines emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants A failure may occur in certain locations such as the following Areas with large amount of oil droplets including machine oil or vapors Salty a...

Страница 12: ...et of the indoor unit is blocked NOTE When the protective device activates turn off the power switch remove the cause and then restart running Cooling Heating operations Each unit can be controlled individually However indoor units connected to the same outdoor unit cannot perform cooling and heating simultaneously When you attempt simultaneous operation indoor units performing cooling are stopped...

Страница 13: ...t exchanger etc expand and contract slightly due to change of temperature indication is lit When cooling operation cannot be performed because another indoor unit performs heating operation Is outdoor temperature out of operation temperature range indication is lit When the manager of the Air to Air Heat Exchanger with DX Coil Unit has fixed the operation to COOL or HEAT and an operation contrary ...

Страница 14: ...the indoor unit will be deleted 3 After confirmation push button to return to the usual display Check code Indoor unit No in which an error occurred 3 2 1 11Specifications Model with a humidifier Model without a humidifier Sound Power Level is less than 70 dBA MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE MMD VNK1002HEXE2 Type Function Cooling and heating dual purpose type Unit configuration Discr...

Страница 15: ...chinery described below Generic Denomination Air conditioner Air to Air Heat Exchanger with DX Coil Unit Model type MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE MMD VNK1002HEXE2 MMD VN502HEXE MMD VN802HEXE MMD VN1002HEXE MMD VN1002HEXE2 Commercial name TOSHIBA Air to Air Heat Exchanger with DX Coil Unit Complies with the provisions of the Machinery Directive Directive 2006 42 EC and the regulatio...

Страница 16: ...CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00ET99915201_00Ta book Page 29 Tuesday February 15 2011 6 45 PM ...

Отзывы: