Table 1. Setting data (CODE No. table (example))
SVM-13085.indb 103
SVM-13085.indb 103
12/24/13 10:56 AM
12/24/13 10:56 AM
0001
*1
Table 2. Type : CODE No.10
Setting
data
Type
Type name abb.
4-way Air Discharge
Cassette Type
MMU-AP****HPUL
EEPROM initial value on the P.C. board for indoor unit
servicing.
0007
Under Ceiling
MMC-AP****HPUL
CAUTION
DN
01
Filter display delay timer
Item
Setting data
Factory-set value
Dirty state of filter
02
Central control address
03
Cooling only
0F
Type
10
Indoor unit capacity
11
Line address
12
Indoor unit address
13
Group address
14
Automatic restart of power failure
28
Selection of option / Trouble input
(TCB-PCUC2E: CN3)
0002 : 2500H
0000 : Standard
00Un/0099 : Unfixed
0000 : No priority
0000 : Heat pump
Depending on model type
According to capacity type
00Un/0099 : Unfixed
0000 : None
00Un/0099 : Unfixed
00Un/0099 : Unfixed
Specific indoor unit priority
04
2A
0002 : None
Ventilating fan control
31
Themo output SW
Timer setting (wired remote controller)
60
5D
Remote controller operation save function
D0
0000 : Unavailable
0000 : Thermo ON
0001 : Enable
0000 : Available
Presence of Application control kit
(TCB-PCUC2E)
Communication protocol
FC
0000 : None
0000 : TCC-LINK
1Fb
Remote controller operation
0000 : Operation possible
Indoor Unit terminating resistance
1FC
0000 : OFF
0000 : Default setting
External static pressure
F6
Heating suction temperature shift
06
0001 : No automatic
Automatic mode
0D
Sensor SW
32
0000 : Body sensor
FS unit adress
FE
00Un/0099 :
Unfixed
Region
E0
0000 : Japan model
Flap type (Wind direction adjustment)
19
Depending on Type
1E
Temperature range of cooling/heating
automatic SW control point
2B
2E
HA terminal (CN61) select
0000 : Usual (HA terminal)
Table 3. Indoor unit capacity : CODE No.11
0000
*1
Setup data
Invalid
018 type
0009
0011
Model
024 type
0013
030 type
0015
036 type
0017
048 type
< Model name MMC-AP****HPUL >
For the above model. Set the CODE no. to
"E0"
the setting data "0000" (initial) to "0001"
"28"
the setting data "0000" (initial) to "0001"
"33"
the setting data "0000" (initial) to "0001"
"7A"
the setting data "0000" (initial) to "0001"
Temperature unit select
33
0001 : Enable
0001 : North America
7A
*1
*2
- 98 -
Содержание MMC-AP0188HPUL
Страница 16: ...2 WIRING DIAGRAM SVM 13085 indb 18 SVM 13085 indb 18 12 24 13 10 56 AM 12 24 13 10 56 AM 16 ...
Страница 99: ...11 EXPLODED VIEWS AND PARTS LIST MMC AP0188HPUL 049 051 050 048 032 031 ACCESSORY PART 025 024 99 ...
Страница 101: ...12 24 13 10 56 AM 12 24 13 10 56 AM MMC AP0248HPUL MMC AP0308HPUL 054 056 055 053 036 035 ACCESSORY PART 029 028 101 ...
Страница 107: ...144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND ...